Troubleshooting
SiBE041213E
57
Service Diagnosis
4. Troubleshooting
4.1
Error Codes and Description
: Displayed only when system-down occurs.
Error Codes
Description
Reference
Page
System
00
Normal
—
U0
Refrigerant shortage
63
U2
Low-voltage detection or over-voltage detection
65
U4
Signal transmission error (between indoor unit and outdoor unit)
67
UA
Unspecified voltage (between indoor unit and outdoor unit)
69
Indoor
Unit
A1
Indoor unit PCB abnormality
58
A5
Freeze-up protection control / heating peak-cut control
59
A6
Fan motor (DC motor) or related abnormality
60
C4
Indoor heat exchanger thermistor or related abnormality
62
C9
Room temperature thermistor or related abnormality
62
Outdoor
Unit
E1
Outdoor unit PCB abnormality
70
E5
OL activation (compressor overload)
72
E6
Compressor lock
74
E7
DC fan lock
75
E8
Input overcurrent detection
76
EA
Four way valve abnormality
77
F3
Discharge pipe temperature control
79
F6
High pressure control in cooling
80
H0
Compressor system sensor abnormality
81
H6
Position sensor abnormality
82
H8
DC voltage / current sensor abnormality (35/42 class only)
84
H9
Outdoor temperature thermistor or related abnormality
85
J3
Discharge pipe thermistor or related abnormality
85
J6
Outdoor heat exchanger thermistor or related abnormality
85
L3
Electrical box temperature rise
87
L4
Radiation fin temperature rise
88
L5
Output overcurrent detection
90
P4
Radiation fin thermistor or related abnormality
85
Summary of Contents for RXS35K2V1B
Page 12: ...SiBE041213E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Page 14: ...SiBE041213E 3 Specifications Part 2 Specifications 1 Specifications 4 ...
Page 59: ...SiBE041213E Remote Controller 48 Part 5 Remote Controller 1 Remote Controller 49 ...
Page 129: ...Revision History Month Year Version Revised contents 05 2013 SiBE041213E First edition ...