background image

 

RXYQ8~1 RXYQ8~12P7YLK
VRVIII system air conditioner

Operation manual

 

1

 

C

 

ONTENTS

 

Page

 

1. Safety cautions .......................................................................... 1

2. What to do before operation ...................................................... 3

3. Remote controller: name and function of each button 

and icon ..................................................................................... 3

4. Changeover switch: Name and function of each switch ............. 3

5. Operation range ......................................................................... 4

6. Operation procedure .................................................................. 4

 

6.1. Cooling, heating, and fan only operation...................................... 4
6.2. Program dry operation ................................................................. 5
6.3. Adjusting the air flow direction ..................................................... 5
6.4. Programming start and stop of the system with timer .................. 5
6.5. Setting the master remote controller ............................................ 6
6.6. Precautions for group control system or two remote controller 

control system .............................................................................. 6

 

7. Energy saving and optimum operation ...................................... 6

8. Maintenance .............................................................................. 7

 

8.1. Maintenance after a long stop period........................................... 7
8.2. Maintenance before a long stop period........................................ 7

 

9. Following symptoms are not air conditioner troubles ................. 7

10. Troubleshooting.......................................................................... 8

11. After-sales service and warranty................................................ 9

 

11.1. After-sales service ....................................................................... 9
11.2. Shortening of "maintenance cycle" and "replacement cycle" 

needs to be considered in following situations ............................. 9

 

1.

S

 

AFETY

 

 

 

CAUTIONS

 

Read the following cautions carefully and use your equipment
properly.

Keep these warning sheets handy so that you can refer to them
if needed.

 

Also, if this equipment is transferred to a new user, make sure to
hand over this user's manual to the new user.

 

Warnings

 

 

It is not good for your health to expose your body to the air flow
for a long time.

 

 

In order to avoid electric shock, fire or injury, or if you detect any
abnormality such as smell of fire, turn off the power supply and
call your dealer for instructions.

 

 

Ask your dealer for installation of the air conditioner.
Incomplete installation performed by yourself may result in a
water leakage, electric shock, and fire.

 

 

Do not place objects in direct proximity of the outdoor unit and
do not let leaves and other debris accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit.
Once in the unit, such animals can cause malfunctions, smoke
or fire when making contact with electrical parts.

 

 

Ask your dealer for improvement, repair, and maintenance.
Incomplete improvement, repair, and maintenance may result in
a water leakage, electric shock and fire.

 

 

Do not insert fingers, rods or other objects into the air inlet or
outlet. When the fan is rotating at high speed, it will cause injury.

 

 

Never let the indoor unit or the remote controller get wet.
It may cause an electric shock or a fire.

 

 

Never use a flammable spray such as hair spray, lacquer or paint
near the unit.
It may cause a fire.

 

 

Never touch the air outlet or the horizontal blades while the
swing flap is in operation.
Fingers may become caught or the unit may break down.

 

 

Never replace a fuse with that of wrong ampere ratings or other
wires when a fuse blows out.
Use of wire or copper wire may cause the unit to break down or
cause a fire.

 

 

Never put any objects into the air inlet or outlet.
Objects touching the fan at high operating speed can be
dangerous.

 

 

Never press the button of the remote controller with a hard,
pointed object.
The remote controller may be damaged.

 

 

Never pull or twist the electric wire of the remote controller.
It may cause the unit to malfunction.

 

 

Never inspect or service the unit by yourself.
Ask a qualified service person to perform this work.

 

 

To prevent refrigerant leak, contact your dealer.
When the system is installed and runs in a small room, it is
required to keep the concentration of the refrigerant, if by any
chance coming out, below the limit. Otherwise, oxygen in the
room may be affected, resulting in a serious accident.

 

 

The refrigerant in the air conditioner is safe and normally does
not leak. If the refrigerant leaks in the room, contact with a fire of
a burner, a heater or a cooker may result in a harmful gas.
Turn off any combustible heating devices, ventilate the room and
contact the dealer where you purchased the unit.
Do not use the air conditioner until a service person confirms
that the portion where the refrigerant leaks is repaired.

 

 

Improper installation or attachment of equipment or accessories
could result in electric shock, short-circuit, leaks, fire or other
damage to the equipment. Be sure to use only accessories
made by Daikin which are specifically designed for use with the
equipment and have them installed by a professional.

 

 

Ask your dealer to move and reinstall the air conditioner.
Incomplete installation may result in a water leakage, electric
shock, and fire.

 

RXYQ8P7Y1K

RXYQ8P7YLK

RXYQ10P7Y1K

RXYQ10P7YLK

RXYQ12P7Y1K

RXYQ12P7YLK

 

VRVIII system air conditioner

 

Operation manual

 

Thank you for purchasing this Daikin air conditioner.
Carefully read this operation manual before using the air
conditioner. It will tell you how to use the unit properly and
help you if any trouble occurs. After reading the manual,
file it away for future reference.

 

WARNING

 

Improper handling can lead to such serious consequences
as death, severe injury or damage to the equipment.

 

NOTE

 

These instructions will ensure proper use of the
equipment.

Be sure to follow these important safety cautions.

4PW41759-1A – 08.2011

Summary of Contents for RXYQ8P7Y1K

Page 1: ...OPERATION MANUAL RXYQ8P7Y1K RXYQ10P7Y1K RXYQ12P7Y1K RXYQ8P7YLK RXYQ10P7YLK RXYQ12P7YLK System air conditioner...

Page 2: ...1 6 2 1 1 6 3 1 10 11 1 1 8 3 5 4 2 7 2 4 3 1 5 1 2 3 4 2 1 2 9 C D A B 13 2 1 5 5 3 4 6 4 3 4 2 1 1 12 1 2 4 3 10 11 12 18 5 13 23 6 14 15 8 9 7 16 17 19 20 21 22 24 1 2 3 4 2 1 1 2 3 4 5 6 1 6 2 6 3...

Page 3: ...e spray such as hair spray lacquer or paint near the unit It may cause a fire Never touch the air outlet or the horizontal blades while the swing flap is in operation Fingers may become caught or the...

Page 4: ...he air conditioner at any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break out In order to avoid electric shock or fire make sure that...

Page 5: ...e Refer to the chapter Explanation of heating operation on page 4 14 TIMER MODE START STOP BUTTON Refer to the chapter 6 4 Programming start and stop of the system with timer on page 5 15 TIMER ON OFF...

Page 6: ...ng the system 6 Press the on off button once again The operation lamp goes off and the system stops operation Explanation of heating operation It may take longer to reach the set temperature for gener...

Page 7: ...d fixed air flow direction setting Movement of the air flow flap See figure 9 For the following conditions a micro computer controls the air flow direction which may be different from the display The...

Page 8: ...roller controls up to 16 indoor units All indoor units are equally set Two remote controller control system Two remote controllers control one indoor unit in case of group control system one group of...

Page 9: ...4 The fan strength does not correspond to the setting The fan strength does no change even if the fan strength adjustment button in pressed During heating operation when the room temperature reaches...

Page 10: ...aker or an earth leakage breaker frequently actuates or the ON OFF switch does not properly work Measure Turn off the main power switch If water leaks from the unit Measure Stop the operation The oper...

Page 11: ...e is long sites with 24 hour air conditioning Recommended replacement cycle of wear parts Table 2 Replacement Cycle list Contact your dealer for details Moving and discarding the unit Contact your dea...

Page 12: ...Copyright 2008 Daikin 4PW41759 1A 08 2011...