Operation manual

6

RXYQ8~1 RXYQ8~12P7YLK

VRVIII system air conditioner

3

Press the timer on/off button.

The timer setting procedure ends. The display "

" or

"

" changes from flashing to constantly lit.

Example: 

(See figure 10)

When the timer is programmed to stop the sysytem after 3 hours and
start the system after 4 hours, the system will stop operating after
3 hours and starts again 1 hour later.

6.5.

Setting the master remote controller

When the system is installed as shown in 

figure 13

 (the outdoor unit

is connected to several indoor units), it is necessary to designate
one of the remote controllers as the master remote controller.

Only the master remote controller can select heating or cooling.

The displays of slave remote controllers show 

 (change-

over under centralized control) and slave remote controllers
automatically follow the operation mode directed by the master
remote controller.

However, it is possible to changeover to program dry with slave
remote controllers if the system is in cooling operation set by the
master remote controller.

How to designate the master remote controller 

(See figure 11)

1

Press the operation mode selector button of the current master
remote controller for 4 seconds.

The display showing 

 (change-over under centralized

control) of all slave remote controllers connected to the same
outdoor unit flash.

2

Press the operation mode selector button of the controller that
you wish to designate as the master remote controller. Then
designation is completed. This remote controller is designated
as the master remote controller and the display showing 
(change-over under centralized control) vanishes.

The displays of other remote controllers show 

 (change-

over under centralized control).

6.6.

Precautions for group control system or two 
remote controller control system

This system provides two other control systems beside individual
control (one remote controller controls one indoor unit) system.
Confirm the following if your unit is of the following control system
type.

Group control system
One remote controller controls up to 16 indoor units. All indoor
units are equally set.

Two remote controller control system
Two remote controllers control one indoor unit (in case of group
control system, one group of indoor units). The unit is
individually operated.

7.

E

NERGY

 

SAVING

 

AND

 

OPTIMUM

 

OPERATION

Observe the following precautions to ensure the system operates
properly.

Adjust the air outlet properly and avoid direct air flow to room
inhabitants.

Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.

Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.

Ventilate often.
Extended use requires special attention to ventilation.

Keep doors and windows closed. If the doors and windows
remain open, air will flow out of your room causing a decrease in
the cooling or heating effect.

Be careful not to cool or heat too much.

Never place objects near the air inlet or the air outlet of the unit.
It may cause deterioration in the effect or stop the operation.

Turn off the main power supply switch to the unit when the unit is
not used for longer periods of time. If the switch is on, it uses
electricity. Before restarting the unit, turn on the main power
supply switch 6 hours before operation to ensure smooth
running. (Refer to "Maintenance" in the indoor unit manual.)

When the display shows 

 (time to clean the air filter), ask a

qualified service person to clean the filters. (Refer to
"Maintenance" in the indoor unit manual.)

Keep the indoor unit and remote control at least 1 m away from
televisions, radios, stereos, and other similar equipment.
Failing to do so may cause static or distorted pictures.

Do not place items under the indoor unit which may be damaged
by water.
Condensation may form if the humidity is above 80% or if the
drain outlet gets blocked.

NOTE

When setting the timer off and on at the
same time, repeat the above procedure from
1 to 3 once again.

After the timer is programmed, the display
shows the remaining time.

Press the timer on/off button once again to
cancel programming. The display
disappears.

NOTE

Contact your dealer in case of changing the
combination or setting of group control and two remote
controller control systems.

4PW41759-1A – 08.2011

Summary of Contents for RXYQ8P7Y1K

Page 1: ...OPERATION MANUAL RXYQ8P7Y1K RXYQ10P7Y1K RXYQ12P7Y1K RXYQ8P7YLK RXYQ10P7YLK RXYQ12P7YLK System air conditioner...

Page 2: ...1 6 2 1 1 6 3 1 10 11 1 1 8 3 5 4 2 7 2 4 3 1 5 1 2 3 4 2 1 2 9 C D A B 13 2 1 5 5 3 4 6 4 3 4 2 1 1 12 1 2 4 3 10 11 12 18 5 13 23 6 14 15 8 9 7 16 17 19 20 21 22 24 1 2 3 4 2 1 1 2 3 4 5 6 1 6 2 6 3...

Page 3: ...e spray such as hair spray lacquer or paint near the unit It may cause a fire Never touch the air outlet or the horizontal blades while the swing flap is in operation Fingers may become caught or the...

Page 4: ...he air conditioner at any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break out In order to avoid electric shock or fire make sure that...

Page 5: ...e Refer to the chapter Explanation of heating operation on page 4 14 TIMER MODE START STOP BUTTON Refer to the chapter 6 4 Programming start and stop of the system with timer on page 5 15 TIMER ON OFF...

Page 6: ...ng the system 6 Press the on off button once again The operation lamp goes off and the system stops operation Explanation of heating operation It may take longer to reach the set temperature for gener...

Page 7: ...d fixed air flow direction setting Movement of the air flow flap See figure 9 For the following conditions a micro computer controls the air flow direction which may be different from the display The...

Page 8: ...roller controls up to 16 indoor units All indoor units are equally set Two remote controller control system Two remote controllers control one indoor unit in case of group control system one group of...

Page 9: ...4 The fan strength does not correspond to the setting The fan strength does no change even if the fan strength adjustment button in pressed During heating operation when the room temperature reaches...

Page 10: ...aker or an earth leakage breaker frequently actuates or the ON OFF switch does not properly work Measure Turn off the main power switch If water leaks from the unit Measure Stop the operation The oper...

Page 11: ...e is long sites with 24 hour air conditioning Recommended replacement cycle of wear parts Table 2 Replacement Cycle list Contact your dealer for details Moving and discarding the unit Contact your dea...

Page 12: ...Copyright 2008 Daikin 4PW41759 1A 08 2011...

Reviews: