10 For the user
Installation and operation manual
27
RXYSQ4~Y1B
VRV IV-S system air conditioner
4P397284-1 – 2015.05
R6T
Thermistor (subcool heat exchanger)
R7T
Thermistor (liquid pipe)
FINTH
Thermistor (fin)
S1NPH
High pressure sensor
S1NPL
Low pressure sensor
S1PH
High pressure switch
S1S
Air control switch (option)
S2S
Cool/heat selector switch (option)
V1R
IGBT power module (A1P)
V2R
Diode module (A1P)
V*T
Insulated gate bipolar transistor (IGBT) N-channel
(A1P)
V*D
Diode (A1P)
X*A
PCB connector
X*M
Terminal strip
X*Y
Connector
X37A
Connector (power supply for option PCB)
Y1E
Electronic expansion valve (main)
Y3E
Electronic expansion valve (subcool heat exchanger)
Y1S
Solenoid valve (4‑way valve)
Z*C
Noise filter (ferrite core)
Z*F (A*P)
Noise filter
Legend for wiring diagram RXYSQ4~6_Y1:
A1P
Printed circuit board (main)
A2P
Printed circuit board (inverter)
BS*
Push buttons (mode, set, return, test, reset) (A1P)
C*
Capacitor (A2P)
DS1
DIP switch (A1P)
F1U, F2U
Fuse (T 31.5 A / 500 V) (A1P)
F1U
Fuse (T 5.0 A / 250 V) (A2P)
F3U, F4U,
F5U
Fuse (T 6.3 A / 250 V) (A1P)
H*P
LED (service monitor orange) (A1P)
HAP
Running LED (service monitor green) (A*P)
K1M
Magnetic contactor (A2P)
K*R
Magnetic relay (A*P)
L1R
Reactor
M1C
Motor (compressor)
M1F
Motor (upper fan)
M2F
Motor (lower fan)
PS
Switching power supply (A2P)
Q1DI
Earth leakage circuit breaker (field supply)
R*
Resistor (A2P)
R1T
Thermistor (air)
R2T
Thermistor (discharge)
R3T
Thermistor (suction 1)
R4T
Thermistor (heat exchanger)
R5T
Thermistor (suction 2)
R6T
Thermistor (subcool heat exchanger)
R7T
Thermistor (liquid pipe)
R10T
Thermistor (fin)
S1NPH
High pressure sensor
S1NPL
Low pressure sensor
S1PH
High pressure switch
S1S
Air control switch (option)
S2S
Cool/heat selector switch (option)
V1R
IGBT power module (A2P)
V2R, V3R
Diode module (A2P)
X*A
PCB connector
X*M
Terminal strip
X*Y
Connector
X37A
Connector (power supply for option PCB)
Y1E
Electronic expansion valve (main)
Y3E
Electronic expansion valve (subcool heat exchanger)
Y1S
Solenoid valve (4‑way valve)
Z*C
Noise filter (ferrite core)
Z*F
Noise filter
For the user
10
About the system
The indoor unit part of VRV IV-S heat pump system can be used for
heating/cooling applications. The type of indoor unit which can be
used depends on the outdoor units series.
NOTICE
Do not use the air conditioner for other purposes. In order
to avoid any quality deterioration, do not use the unit for
cooling precision instruments, food, plants, animals or
works of art.
NOTICE
For future modifications or expansions of your system:
A full overview of allowable combinations (for future
system extensions) is available in technical engineering
data and should be consulted. Contact your installer to
receive more information and professional advice.
INFORMATION
▪ Combination of VRV DX and RA DX indoor units is not
allowed.
▪ Combination of RA DX and AHU indoor units is not
allowed.
▪ Combination of RA DX and aircurtain indoor units is not
allowed.