background image

English

8

Press AIRFLOW DIRECTION 
ADJUST/SETTING button to 
select the air direction of your 
choice.

The AIRFLOW DIRECTION 
display stops swinging and the 
airflow direction is fixed (Fixed 
airflow direction setting).

MOVEMENT OF THE HORIZONTAL BLADE

For the following conditions, micro computer 
controls the airflow direction so it may be different 
from the display. 

NOTE

When group control is performed on the 
simultaneous operation system (twin and triple), 
airflow direction cannot be individually set on the 
slave units.

Operation 
mode

COOLING

AUTOMATIC 
COOLING

PROGRAM DRY

HEATING

AUTOMATIC 
HEATING

Up and down 
direction

Air blows in the 
automatic set direction 
for a period of time to 
prevent condensation 
on the horizontal 
blades.

When operating 
continuously at 
downward airflow 
direction

The airflow direction 
becomes horizontal so 
that it does not blow 
directly toward your 
body.

When room 
temperature is 
higher than the set 
temperature

When the HEATING 
OPERATION starts 
or during the 
DEFROST 
OPERATION (if frost 
forms on the outdoor 
unit)

1

Indoor unit (Slave)

2

Indoor unit (Master)

3

Outdoor unit

4

Remote controller

5

Twin

6

Triple

5

1

1

2

3

3

4

6

Recommended airflow direction positions

We recommend using the airflow in the position 
listed above when fixing the airflow direction.

7. OPTIMUM OPERATION

Observe the following precautions to ensure the air 
conditioner operates.

Prevent direct sunlight from the window by using 
curtains or blinds during the COOLING 
OPERATION.

Keep doors and windows closed. If the doors and 
windows remain open, room air will flow out and 
decrease the effect of cooling and heating.

Never place objects near the air inlet and the air 
outlet of the air conditioner. It may decrease the 
effect or stop the operation.

Adjust the room temperature properly for a 
comfortable environment. Avoid excessive 
heating or cooling.
Not doing so wastes electricity.

When the display shows "

" or "Time to clean 

filter", ask a qualified service person to clean the 
filters.
(Refer to "

MAINTENANCE (FOR SERVICE 

PERSONNEL)

" on page 9.)

Operating the indoor unit with stained air filter 
may decrease capacity or cause malfunction.

Install TVs, radios, and stereos 1 m or more away 
from the indoor unit and remote controller.
Images may become fuzzy and noise may be 
generated.

Turn off the power circuit breaker when it is not in 
use for a long period. When the power circuit 
breaker is turned on, small amount of power is 
consumed even if the air conditioner is not in 
operation. (*1)
Turn off the power circuit breaker for saving 
energy. When reoperating, turn on the power 
circuit breaker 6 hours before operation for 
smooth running.
(Refer to "

MAINTENANCE (FOR SERVICE 

PERSONNEL)

" on page 9) (*2)

*1 The consumed power while the outdoor unit is 

not in operation depends on the model.

*2 The setting before the power circuit breaker is 

cut off is stored. (The timer setting is cleared.)

Cooling

Heating

4PEN465543-1D.book  Page 8  Monday, February 25, 2019  9:26 AM

Summary of Contents for RZAG100

Page 1: ...OPERATION MANUAL FUA71AVEB9 FUA100AVEB9 FUA125AVEB9 Split system air conditioners 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Page 2: ...can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruct...

Page 3: ...a utility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge current from lightning or other sources may cause damage to the ai...

Page 4: ...animals or works of art as this may adversely affect the performance quality and or longevity of the object concerned Do not install the air conditioner at any place where there is a danger of flammab...

Page 5: ...ontroller when used as simulta neous operation A Pair system or simultaneous operation system B Multi system 1 Unit with remote controller 2 Unit without remote controller when used as simulta neous o...

Page 6: ...ure The setting temperature range of the remote controller is 16 C 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for installation Is the air conditioner installed at a well...

Page 7: ...your system type To protect the air conditioner turn on the main power switch 6 hours before operation Do not shut off the power supply during seasonal use of the air conditioner This is required in...

Page 8: ...irection becomes horizontal The remote controller displays the fan speed and airflow direction that are set CHARACTERISTICS OF THE PROGRAM DRY OPERATION This operation lowers the humidity without lowe...

Page 9: ...r operates Prevent direct sunlight from the window by using curtains or blinds during the COOLING OPERATION Keep doors and windows closed If the doors and windows remain open room air will flow out an...

Page 10: ...nstable it may cause injuries due to fall and stumbling NOTE Do not remove the air filter unless for cleaning It may cause failure Do not attach substance such as paper towels other than the specified...

Page 11: ...e closing the suction grille confirm if the strap is not sticking out from the side of the suction grille If the air filter is extremely contaminated wash it with neutral detergent using a soft brush...

Page 12: ...HAT TO DO WHEN START UP AFTER A LONG STOP Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and...

Page 13: ...off the power circuit breaker during seasonal use of the HEATING OPERATION I THE AIR CONDITIONER DOES NOT OPERATE The air conditioner does not restart immediately after the ON OFF button is pressed T...

Page 14: ...t swing when the remote controller displays the swing operation HEATING OPERATION This is because the airflow direction is controlled so it is horizontal direction after the operation starts or when t...

Page 15: ...by temperature change makes this noise VIII DUST FROM THE INDOOR UNITS Dust may blow out from the unit after starting operation from long resting time Dust absorbed by the unit blows out IX THE INDOOR...

Page 16: ...to an appropriate temperature fan speed and airflow direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and airflow direction Check if the doors or the...

Page 17: ...local and national legislation Units and waste batteries must be treated at a specialized treatment facility for re use recycling and recovery By ensuring correct disposal you will help to prevent pot...

Page 18: ...4P465543 1D 2019 02 Copyright 2017 Daikin 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Reviews: