Field settings
ESIE04-01
4–12
Part 4 – Commissioning and Test Run
3
1
4
5
2.3
How to Change the Field Settings with the Wireless Remote Controller
Optional
accessories
If optional accessories are mounted on the indoor unit, the indoor unit setting may have to be changed.
Refer to OH98-2 or the installation manual (optional handbook) for each optional accessory.
Wireless remote
controller
The illustration below shows the wireless remote controller.
Setting
To set the field settings, you have to change:
P
“Mode No.”
P
“First code No.”
P
“Second code No.”.
To change the field settings, proceed as follows:
RESERVE button
INSPECTION/TEST button
Mode No.
Field setting mode
UP button
DOWN button
First code No.
Second code No.
MODE button
Step
Action
1
Hold down the INSPECTION/TEST button for at least 4 s during normal mode to enter
the “Field setting mode”.
2
Press the MODE button to select the desired “Mode No.”.
3
Press the UP button to select the “First code No.”.
4
Press the DOWN button to select the “Second code No.”
5
Press the RESERVE button to set the present settings.
6
Press the INSPECTION/TEST button to return to the “Normal mode”.
RZQ - Final.book Page 12 Wednesday, September 8, 2004 8:40 AM
Summary of Contents for RZQ71~125B7V3B
Page 1: ...Service Manual ESIE04 01 RZQ71 125B7V3B Sky Air Inverter R 410A B series ...
Page 2: ......
Page 24: ...ESIE04 01 1 2 Part 1 System Outline 3 1 1 5 ...
Page 32: ...General Outline Outdoor Units ESIE04 01 1 10 Part 1 System Outline 3 1 1 4 5 ...
Page 64: ...General Outline Indoor Units ESIE04 01 1 42 Part 1 System Outline 3 1 1 4 5 ...
Page 76: ...Specifications ESIE04 01 1 54 Part 1 System Outline 3 1 1 4 5 ...
Page 92: ...Functional Diagrams ESIE04 01 1 70 Part 1 System Outline 3 1 1 4 5 ...
Page 94: ...ESIE04 01 1 72 Part 1 System Outline ...
Page 122: ...Wiring Diagrams ESIE04 01 1 100 Part 1 System Outline 3 1 1 4 5 ...
Page 140: ...ESIE04 01 2 2 Part 2 Functional Description 3 1 2 5 ...
Page 162: ...General Functionality ESIE04 01 2 24 Part 2 Functional Description 3 1 2 4 5 ...
Page 200: ...Outdoor Unit Functional Concept ESIE04 01 2 62 Part 2 Functional Description 3 1 2 4 5 ...
Page 202: ...ESIE04 01 3 2 Part 3 Troubleshooting 3 1 3 5 ...
Page 288: ...Error Codes Outdoor Units ESIE04 01 3 88 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 312: ...Additional Checks for Troubleshooting ESIE04 01 3 112 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 314: ...ESIE04 01 4 2 Part 4 Commissioning and Test Run 3 1 4 5 ...
Page 356: ...ESIE04 01 5 2 Part 5 Disassembly and Maintenance 3 1 5 ...
Page 484: ...ESIE04 01 viii Index 3 1 4 5 ...