background image

 

Operation manual

3

ADEQ71~125A7VEB

Split system air conditioners

4P335706-1 – 2012.11

O

PERATION

 

RANGE

If operating outside the following conditions, safety devices may
activate, rendering the air conditioner inoperable or may cause the
indoor unit to sweat.

The setting temperature range of the remote controller is 16°C–32°C.

(DB=dry bulb, WB=wet bulb, 

=cooling, 

=heating, 

=indoor,

=outdoor, =temperature, 

=humidity)

O

PERATION

 

PROCEDURE

O

PTIMUM

 

OPERATION

Observe the following precautions to ensure the system operates
properly.

Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.
Notice that it may take some time for the room temperature to
reach the set temperature. Consider therefore to take advantage
of the timer setting possibilities.

Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.

Ventilate the room regularly. Using the unit for long periods of
time requires attentive ventilation of the room.

Do not operate the air conditioner when using a room
fumigation-type insecticide.
Failure to observe this could cause the chemicals to become
deposited in the unit, which could endanger the health of those
who are hypersensitive to chemicals.

Keep doors and windows closed. If the doors and windows
remain open, room air will flow out and decrease the effect of
cooling and heating.

Never place objects near the air inlet and the air outlet of the
unit. It may retard effectiveness or cause operation to stop.

Turn  off the main power supply switch when not using for long
periods of time. Electricity is consumed as long as the switch is
on. Turn off the main power supply switch in order to save
energy. Turn on the main power supply switch 6 hours before
restarting operation in order to ensure smooth operation. (Refer
to 

"Maintenance" on page 3

.)

When the display shows "

" (TIME TO CLEAN AIR

FILTER), have a qualified service person to clean the filters.
(Refer to 

"Maintenance" on page 3

.)

M

AINTENANCE

Read the operation manual supplied with the remote
controller.

If a function that is not available is selected, the
message NOT AVAILABLE will appear.

To  protect the unit, turn on the main power switch
6 hours before operation.

If the main power supply is turned off during
operation, operation will restart automatically after the
power turns back on again.

NOTE

Set the temperature within the ranges mentioned
under 

"Operation range" on page 3

.

18-35
14-28

AZQS~B

80%

–5~46

°

C DB

°

C WB

–14~21
–15~15.5

10-27

°

C DB

°

C WB

AZQS~B

°

C DB

°

C

Do not use the air conditioner for other purposes.

In order to avoid any quality deterioration, do not use the
unit for cooling precision instruments, food, plants, animals
or works of art.

CAUTION

Only a qualified service person is allowed to perform
maintenance.

Before obtaining access to terminal devices, all power
supply circuits must be interrupted.

To clean the air conditioner or air filter, be sure to stop
operation and turn all power supplies off.
Otherwise, an electric shock and injury may result.

Do not wash the air conditioner with water.
Doing so may result in an electric shock.

Be careful with scaffoldings.
Caution must be exercised when working in high
places.

After a long use, check the unit stand and fitting for
damage. If damaged, the unit may fall and cause
injury.

Do not touch the heat exchanger fins.
The fins are sharp and could result in cutting injuries.

When cleaning the heat exchanger, be sure to remove
the control box, fan motor, drain pump and float
switch. Water or detergent may deteriorate the
insulation of electronic components and result in
burn-out of these components.

Caution for drain socket

Do not remove the drain pipe plug. Water might leak out.

The drain outlet is only used to discharge water if the drain
pump is not used or before maintenance. Gently put in and
out the drain plug. Excessive force may deform the drain
socket of the drain pan.

Pulling out the plug 

Do not wiggle the plug up and down

Pushing in the plug

Set the plug and push it by using a Phillips
screwdriver

1

1

Drain plug

1

2

1

Drain plug

2

Phillips screwdriver

Summary of Contents for Siesta ADEQ71A7VEB

Page 1: ...OPERATION MANUAL ADEQ71A7VEB ADEQ100A7VEB ADEQ125A7VEB Split system air conditioners ...

Page 2: ... can refer to it whenever necessary If the equipment is transferred to a new user be sure also to hand over the manual Warning Be aware that prolonged direct exposure to cool or warm air from the air conditioner or to air that is too cool or too warm can be harmful to your physical condition and health When the air conditioner is malfunctioning giving off a burning odour etc turn off power to the ...

Page 3: ...ts on the unit Injury may result if the unit becomes loose and falls Do not expose plants or animals directly to air flow from the unit as this may cause adverse effects Do not wash the air conditioner with water as this may result in electric shocks or fire This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experien...

Page 4: ...Refer to Maintenance on page 3 MAINTENANCE Read the operation manual supplied with the remote controller If a function that is not available is selected the message NOT AVAILABLE will appear To protect the unit turn on the main power switch 6 hours before operation If the main power supply is turned off during operation operation will restart automatically after the power turns back on again NOTE ...

Page 5: ...s turned off Clean the air filter and the exterior Be sure to replace the air filter to its original place after cleaning Refer to Maintenance on page 3 NOT A MALFUNCTION OF THE AIR CONDITIONER The following symptoms do not indicate air conditioner malfunction The system does not operate The system does not restart immediately after the ON OFF button is pressed If the OPERATION lamp lights the sys...

Page 6: ...tify your dealer and inform him her of the display If the system does not operate properly except for the above mentioned case and none of the above mentioned malfunctions are evident investigate the system according to the following procedures If the system does not operate at all Check if there is a power failure Wait until power is restored If power failure occurs during operation the system au...

Page 7: ......

Page 8: ...4P335706 1 2012 11 Copyright 2012 Daikin ...

Reviews: