background image

6 Energy saving and optimum operation

Operation manual

15

ATXM-A
Daikin room air conditioner
3P728539-4 – 2023.06

2

Change  to  the  SP  menu 

  by  pressing 

  once  or 

repeatedly.

(5 sec.) 

3

Hold 

 for at least 2 seconds to confirm the selection.

Result: 

  is  blinking.  The  Daikin  eye  alternates  between

white and partly green. Communication is OFF.

4

Press 

 to exit the menu.

Result: 

The display will return to the default screen.

6

Energy saving and optimum
operation

INFORMATION

▪ Even if the unit is turned OFF, it consumes electricity.

▪ When the power turns back on after a power break, the

previously selected mode will be resumed.

CAUTION

NEVER  expose  little  children,  plants  or  animals  directly  to
the airflow.

NOTICE

Do NOT place objects below the indoor and/or outdoor unit
that  may  get  wet.  Otherwise  condensation  on  the  unit  or
refrigerant pipes, air filter dirt or drain blockage may cause
dripping,  and  objects  under  the  unit  may  get  dirty  or
damaged.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air
conditioner and do NOT use sprays near the unit. Doing so
may result in a fire.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

7

Maintenance and service

7.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance.

About the refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

Applicable  legislation  on 

fluorinated  greenhouse  gases

requires  that  the  refrigerant  charge  of  the  unit  is  indicated
both in weight and CO

2

 equivalent.

Formula  to  calculate  the  quantity  in  CO

2

  equivalent

tonnes:

  GWP  value  of  the  refrigerant  ×  total  refrigerant

charge [in kg]/1000

Contact your installer for more information.

NOTICE

Maintenance  MUST  be  done  by  an  authorised  installer  or
service agent.

We  recommend  performing  maintenance  at  least  once  a
year. However, applicable legislation might require shorter
maintenance intervals.

WARNING

▪ The  refrigerant  inside  the  unit  is  mildly  flammable,  but

normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater,  or  a  cooker,  this  may  result  in  fire,  or  the
formation of a harmful gas.

▪ Turn  OFF  any  combustible  heating  devices,  ventilate

the room, and contact the dealer where you purchased
the unit.

▪ Do  NOT  use  the  unit  until  a  service  person  confirms

that the part from which the refrigerant leaked has been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

WARNING

The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating  ignition  sources  (e.g.  open  flames,  an  operating
gas  appliance,  or  an  operating  electric  heater).  The  room
size shall be as specified in the General safety precaution.

DANGER: RISK OF ELECTROCUTION

To  clean  the  air  conditioner  or  air  filter,  be  sure  to  stop
operation  and  turn  all  power  supplies  OFF.  Otherwise,  an
electrical shock and injury may result.

WARNING

To prevent electrical shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet hands.

▪ Do NOT place any objects containing water on the unit.

CAUTION

After  a  long  use,  check  the  unit  stand  and  fitting  for
damage. If damaged, the unit may fall and result in injury.

CAUTION

Do  NOT  touch  the  heat  exchanger  fins.  These  fins  are
sharp and could result in cutting injuries.

Summary of Contents for Siesta ATXM20A2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner ATXM20A2V1B ATXM25A2V1B ATXM35A2V1B ATXM50A2V1B ATXM20A5V1B ATXM25A5V1B ATXM35A5V1B ATXM50A5V1B...

Page 2: ...11 1 Precautions when using the wireless LAN 13 5 11 2 To install the ONECTA app 13 5 11 3 To set the wireless connection 13 6 Energy saving and optimum operation 15 7 Maintenance and service 15 7 1...

Page 3: ...rmation contact your installer or local authority Batteries are marked with the following symbol This means that the batteries may NOT be mixed with unsorted household waste If a chemical symbol is pr...

Page 4: ...the unit until a service person confirms that the part from which the refrigerant leaked has been repaired WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means...

Page 5: ...are no naked flames The refrigerant itself is entirely safe non toxic and mildly flammable but it will generate toxic gas when it accidentally leaks into a room where combustible air from fan heaters...

Page 6: ...w and Intelligent eye operation button h Select button i Clock and indoor unit display brightness button j OFF ON timer operation buttons k Weekly timer operation buttons l Flash Streamer air cleaning...

Page 7: ...it runs outside its operation range 5 2 Operation mode and temperature setpoint When Adjust the system operation mode and set the temperature when you want to Heat up or cool down a room Blow air in a...

Page 8: ...aries according to the operation mode The flap will stop at the upper position when the airflow rate is changed to low during the up and down swing setting 5 4 1 To adjust vertical airflow direction 1...

Page 9: ...r that operation returns to the previously set mode 2 Press to stop Result disappears from the LCD Note Powerful operation can be set only when the unit is running If you press or if you change operat...

Page 10: ...ions Refer to 4 3 To set the clock 46 5 9 1 24 hour clock OFF ON timer setting To start stop OFF timer operation 1 Press to start Result is displayed on the LCD and blinks and the day of the week disa...

Page 11: ...re is for the wireless remote control only However we recommend to perform the weekly timer setting using the ONECTA app Refer to 5 11 Wireless LAN connection 4 13 for more information With this opera...

Page 12: ...complete reservation of the selected day of the week will be copied 1 Press 2 Press or to select the day of the week to be copied 3 Press Result The reservation of the selected day of the week will b...

Page 13: ...uipment E g persons using cardiac pacemakers or defibrillators This product may cause electromagnetic interference Auto control equipment E g automatic doors or fire alarm equipment This product may c...

Page 14: ...ber 414 5 Press to exit the menu Result The display will return to the default screen To connect using SSID and KEY number 1 On home screen menu hold for at least 5 seconds while the unit is not opera...

Page 15: ...ty in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Contact your installer for more information NOTICE Maintenance MUST be done by an authorised installer or s...

Page 16: ...se a scrubbing brush Possible consequence The surface finishing peels off As an end user you may NEVER clean inside parts of the unit by yourself this work must be performed by a qualified service per...

Page 17: ...anel Align the shafts with the slots and push them all the way in 2 Close the front panel slowly press at both sides and at the centre 8 Troubleshooting If one of the following malfunctions occur take...

Page 18: ...2023 06 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be...

Page 19: ......

Page 20: ...TANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P728539 4 2023 06 Copyright 20...

Reviews: