2
|
Components
Service manual
97
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01C – 2020.07
f
a
d
c
b
e
a
Electrical power supply wiring
b
Wire terminals
c
Screws
d
Wire clamp
e
Screws
f
Right side plate assembly
3
Connect the electrical power supply wiring to the wire terminals.
4
Install the wire clamp and fix it using the screws.
5
Connect all connectors to the main PCB.
INFORMATION
Use the wiring diagram and connection diagram for correct installation of the
connectors, see
WARNING
When reconnecting a connector to the PCB, make sure to connect it on the correct
location and do NOT apply force, as this may damage the connector or connector
pins of the PCB.
6
Fix the wiring to the switch box using a new cable tie.