Specifications
SiE12-411
46
Specifications
Floor / Ceiling Suspended Dual Type
50Hz 220-230-240V / 60Hz 220-230V
Model
FLX25AVMA
FLX35AVMA
Cooling
Heating
Cooling
Heating
Rated Capacity
2.5kW Class
3.5kW Class
Front Panel Color
Almond White
Almond White
Air Flow Rates
m³/min
(cfm)
H
7.6 (268)
9.2 (325)
8.7 (307)
10.0 (353)
M
6.8 (240)
8.3 (293)
7.7 (272)
9.0 (318)
L
6.0 (212)
7.4 (261)
6.6 (233)
8.0 (282)
SL
5.2 (184)
6.6 (233)
5.6 (198)
7.1 (251)
Fan
Type
Sirocco Fan
Sirocco Fan
Motor Output
W
34
34
Speed
Steps
5 Steps, Silent and Auto
5 Steps, Silent and Auto
Air Direction Control
Right, Left, Horizontal and Downward
Right, Left, Horizontal and Downward
Air Filter
Removal-Washable-Mildew Proof
Removal-Washable-Mildew Proof
Running Current (Rated)
A
0.32-0.32-0.32/0.34-0.34
0.34-0.34-0.34/0.37-0.37
0.36-0.36-0.36/0.39-0.39
0.36-0.36-0.36/0.39-0.39
Power Consumption (Rated)
W
68-70-72/72-74
72-74-76/76-79
76-78-80/80-84
76-78-80/80-83
Power Factor
%
96.6-95.1-93.8/96.3-94.6
96.3-94.6-93.1/93.4-92.8
96.0-94.2-92.6/93.2-93.6
96.0-94.2-92.6/93.2-92.5
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
490×1,050×200
490×1,050×200
Packaged Dimensions (W×D×H)
mm
1,100×566×280
1,100×566×280
Weight
kg
16
16
Gross Weight
kg
22
22
Operation
Sound
H/M/L/SL
dBA
37/34/31/28
37/34/31/28
38/35/32/29
39/36/33/30
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
12.7
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D036690
3D036691
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Model
FLX50AVMA
FLX60AVMA
Cooling
Heating
Cooling
Heating
Rated Capacity
5.0kW Class
5.7kW Class
Front Panel Color
Almond White
Almond White
Air Flow Rates
m³/min
(cfm)
H
11.4 (402)
12.1 (427)
12.0 (424)
12.8 (452)
M
10.0 (353)
9.8 (346)
10.6 (374)
10.6 (374)
L
8.5 (300)
7.5 (265)
9.3 (328)
8.4 (297)
SL
7.5 (265)
6.8 (240)
8.3 (293)
7.5 (265)
Fan
Type
Sirocco Fan
Sirocco Fan
Motor Output
W
34
34
Speed
Steps
5 Steps, Silent and Auto
5 Steps, Silent and Auto
Air Direction Control
Right, Left, Horizontal and Downward
Right, Left, Horizontal and Downward
Air Filter
Removal-Washable-Mildew Proof
Removal-Washable-Mildew Proof
Running Current (Rated)
A
0.45-0.45-0.45/0.48-0.48
0.45-0.45-0.45/0.48-0.48
0.47-0.47-0.47/0.51-0.51
0.45-0.45-0.45/0.48-0.48
Power Consumption (Rated)
W
94-96-98/98-100
94-96-98/98-100
96-98-100/100-104
94-96-98/98-101
Power Factor
%
94.9-92.8-90.7/92.8-90.6
94.9-92.8-90.7/92.8-90.6
92.8-90.7-88.7/89.1-88.7
94.9-92.8-90.7/92.8-91.5
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
490×1,050×200
490×1,050×200
Packaged Dimensions (W×D×H)
mm
1,100×566×280
1,100×566×280
Weight
kg
17
17
Gross Weight
kg
24
24
Operation
Sound
H/M/L/SL
dBA
47/43/39/36
46/41/35/32
48/45/41/38
47/42/37/34
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
15.9
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D036692
3D036693
Summary of Contents for Super Multi NX C-Series
Page 6: ...SiE12 411 Table of Contents v Index i Drawings Flow Charts v...
Page 7: ...SiE12 411 vi Table of Contents...
Page 67: ...Specifications SiE12 411 56 Specifications...
Page 171: ...Instruction SiE12 411 160 System Configuration...
Page 225: ...Check SiE12 411 214 Service Diagnosis...
Page 295: ...SiE12 411 iv Index...