SiBE121021_C
284
Service Diagnosis
Part 6
Service Diagnosis
1. Troubleshooting with LED ...................................................................286
2. Problem Symptoms and Measures .....................................................289
3. Service Check Function ......................................................................290
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series........................299
4. Code Indication on Remote Controller ................................................306
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series........................306
5. Troubleshooting for RA Indoor Unit - F(C)TXG,
FTXS, ATXS, FVXS, FLK(X)S, FDK(X)S Series.................................308
Indoor Unit PCB Abnormality ...............................................................308
Freeze-up Protection Control or Heating Peak-cut Control ..................309
Fan Motor or Related Abnormality .......................................................311
Thermistor or Related Abnormality (Indoor Unit)..................................314
Front Panel Open / Close Fault (FTXG and CTXG Series)..................315
Signal Transmission Error (between Indoor Unit and Outdoor Unit) ....316
Unspecified Voltage (between Indoor Unit and Outdoor Unit) .............318
6. Troubleshooting for SA Indoor Unit - FFQ, FCQ,
FDBQ, FBQ, FHQ Series ....................................................................319
Indoor Unit PCB Abnormality ...............................................................319
Drain Water Level System Abnormality................................................320
Fan Motor or Related Abnormality .......................................................322
Swing Motor Lock (FHQ Series)...........................................................324
Drain System Abnormality....................................................................325
Thermistor or Related Abnormality.......................................................326
Remote Controller Thermistor Abnormality ..........................................328
Signal Transmission Error
(between MAIN Remote Controller and SUB Remote Controller)........330
7. Troubleshooting for Outdoor Unit........................................................333
Outdoor Unit PCB Abnormality.............................................................335
OL Activation (Compressor Overload) .................................................336
Compressor Lock .................................................................................337
Input Overcurrent Detection .................................................................339
Discharge Pipe Temperature Control...................................................340