SiBE121021_C
Service Check Function
Service Diagnosis
299
3.2
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
3.2.1 Relations between Modes
BRC1D528, BRC7E530W/531W, BRC7F532F/533F, BRC7EA63W/66
The following modes can be selected by using the [Inspection / Test] button on the remote
controller.
Indoor unit settings can be made.
z
z
Service data can be obtained.
z
z
Service settings can be made.
z
z
Following codes can be checked.
z
z
Press the
[Inspection / Test]
button once.
(R11277)
Press the
[Inspection / Test]
button once.
After 10 seconds
Thermostat is forcibly turned on.
Press the
[Inspection / Test]
button for more than 4 seconds.
Field
setting
mode
Service
mode
Normal
mode
Trial
operation
mode
Inspection
mode
Press the
[Inspection / Test]
button once.
Press the
[Inspection / Test]
button for more than 4 seconds.
Press the
[Inspection / Test]
button once
or leave the remote controller untouched
for 30 minutes.
Filter cleaning sign time
Others
Error code history
Temperature data of various sections
Forced fan ON
Airflow rate setting
Error codes
Indoor model code