background image

32

TROUBLE SHOOTING

Trouble Shooting

The following cases are not air conditioner troubles but have some reasons. You may just continue using it. 

These cases are not troubles.

Case

Explanation

Operation does not start soon.

• When ON/OFF button was pressed 

soon after operation was stopped.

• When the mode was reselected.

• This is to protect the air conditioner.

You should wait for about 3 minutes.

Hot air does not flow out soon 
after the start of heating 
operation.

• The air conditioner is warming up. You should wait for 1 to 4 minutes.

(The system is designed to start discharging air only after it 
has reached a certain temperature.)

The heating operation stops suddenly 
and a flowing sound is heard.

• The system is taking away the frost on the outdoor unit.

You should wait for about 4 to 12 minutes.

The outdoor unit emits water or 
steam.

In HEAT mode
• The frost on the outdoor unit melts into water or steam 

when the air conditioner is in defrost operation.

In COOL or DRY mode
• Moisture in the air condenses into water on the cool 

surface of outdoor unit piping and drips.

Mist comes out of the indoor 
unit.

This happens when the air in the room is cooled into mist by 
the cold airflow during cooling operation.

This is because the air in the room is cooled by the heat 
exchanger and becomes mist during defrost operation.

The indoor unit gives out odour.

This happens when smells of the room, furniture, or cigarettes 
are absorbed into the unit and discharged with the airflow.
(If this happens, we recommend you to have the indoor unit washed by a 
technician. Consult the service shop where you bought the air conditioner.)

The outdoor fan rotates while 
the air conditioner is not in 
operation.

After operation is stopped:
• The outdoor fan continues rotating for another 60 seconds 

for system protection.

While the air conditioner is not in operation:
• When the outdoor temperature is very high, the outdoor 

fan starts rotating for system protection.

The operation stopped 
suddenly.
(OPERATION lamp is on.)

For system protection, the air conditioner may stop operating 
on a sudden large voltage fluctuation.
It automatically resumes operation in about 3 minutes.

No remote controller signals are 
displayed.
The remote controller sensitivity is low.
The display is low in contrast or 
blacked out.
The display runs out of control.

• The batteries are dying and the remote controller is malfunc-

tioning. Replace all the batteries with new size AAA alkaline 
batteries. For details, refer to “To set the batteries” of this 
manual. (page 7.)

 *  If the reset button is provided, press the reset button after the 

batteries are replaced.

The ON/OFF TIMER does not 
operate according to the 
settings.

• Check if the ON/OFF TIMER and the WEEKLY TIMER are 

set to the same time. 
Change or disable the settings in the WEEKLY TIMER. 
(page 23.)

01_EN_3P207037-1B.fm  Page 32  Friday, September 28, 2007  2:04 PM

Summary of Contents for Super Multi NX FTXS50G2V1B

Page 1: ...Deutsch English Fran ais Nederlands Espa ol Italiano Portugues DAIKIN ROOM AIR CONDITIONER Operation Manual T rk e MODELS FTXS20G2V1B FTXS25G2V1B FTXS35G2V1B FTXS42G2V1B FTXS50G2V1B...

Page 2: ...Y COOL HEAT FAN Operation 10 Adjusting the Airflow Direction 12 COMFORT AIRFLOW and INTELLIGENT EYE Operation 14 POWERFUL Operation 17 OUTDOOR UNIT QUIET Operation 18 ECONO Operation 19 TIMER Operatio...

Page 3: ...th our service staff Do not attempt to install the air conditioner by your self Incorrect work will result in water leakage electric shocks or fire For installation consult the dealer or a qualified t...

Page 4: ...the unit Leaves are a hotbed for small animals which can enter the unit Once in the unit such animals can cause malfunctions smoke or fire when making contact with electrical parts Do not operate the...

Page 5: ...4 Names of parts Indoor Unit 16 14 13 15 12 1 3 4 5 7 9 11 10 8 6 2...

Page 6: ...gain to stop it The operation mode refers to the following table This switch is useful when the remote controller is missing 13 Operation lamp green 14 TIMER lamp yellow page 20 15 INTELLIGENT EYE lam...

Page 7: ...n mode AUTO DRY COOL HEAT FAN page 10 8 QUIET button OUTDOOR UNIT QUIET operation page 18 9 ECONO button ECONO operation page 19 10 SWING button Horizontal blades flaps page 12 11 SWING button Vertica...

Page 8: ...ies together When the system is not used for a long time take the batteries out The batteries will last for approximately one year If the remote controller display begins to fade and the degradation o...

Page 9: ...utton to set the clock to the present time Holding down or button rapidly increases or decreases the time display 5 Press CLOCK button Always point the remote controller at the indoor unit when pushin...

Page 10: ...perating If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker OFF Use the air conditioner in the following conditions The operation of the...

Page 11: ...e button advances the mode setting in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To c...

Page 12: ...m switches into defrosting operation to take away the frost During defrosting operation hot air does not flow out of indoor unit A pinging sound may be heard during defrosting operation which however...

Page 13: ...flaps will begin to swing 2 When the flaps have reached the desired position press SWING button once more The flaps will stop moving disappears from the LCD To adjust the vertical blades louvers 3 Pr...

Page 14: ...mensional airflow circulates cold air which tends to collected at the bottom of the room and hot air which tends to collect near the ceiling throughout the room preventing areas of cold and hot develo...

Page 15: ...a different setting option is displayed on the LCD To cancel operation 2 Press COMFORT SENSOR button Press the button to select Blank Display Operation mode Explanation COMFORT AIRFLOW The flaps will...

Page 16: ...e cooling so that the airflow will be directed upward The flaps will move downward while heating so that the airflow will be directed downward The INTELLIGENT EYE sensor according to the following sit...

Page 17: ...tions simultaneously When both of them are in use the air conditioner will not direct the airflow towards the people Sensor may not detect moving objects further than 5m away Check the application ran...

Page 18: ...n POWERFUL Operation cannot be used together with ECONO QUIET or COMFORT Operation Priority is given to the function of whichever button is pressed last POWERFUL Operation can only be set when the uni...

Page 19: ...IET button again disappears from the LCD NOTE Note on OUTDOOR UNIT QUIET operation If using a multi system this function will work only when the OUTDOOR UNIT QUIET operation is set on all operated ind...

Page 20: ...the connecting outdoor unit NOTE ECONO Operation can only be set when the unit is running Pressing the OFF button causes the setting to be canceled and the disappears from the LCD ECONO operation is a...

Page 21: ...utton changes the setting rapidly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel the OFF TIMER Operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIMER is set the pre...

Page 22: ...tton changes the setting rapidly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A s...

Page 23: ...the copy mode ensures ease of making reservations The use of ON ON ON ON settings for example makes it possible to schedule operating mode and set temperature changes Furthermore by using OFF OFF OFF...

Page 24: ...SELECT button to select the desired mode and or will flash Go to STEP 9 if no setting is selected 5 Press NEXT button The weekly mode will be set and blink 6 Press SELECT button to select the desired...

Page 25: ...n the remote controller settings just before the operation Both WEEKLY TIMER and ON OFF timer cannot be used at the same time The ON OFF timer has priority if it is set while WEEKLY TIMER is still act...

Page 26: ...f the week The whole reservation of the selected day of the week will be copied To continue copying the settings to other days of the week repeat STEP 4 and STEP 5 6 Press button Exit copy mode NOTE C...

Page 27: ...in unit and check for a receiving tone This operation is not effective while WEEKLY TIMER is being set All reservations will be canceled Canceling individual reservations This function can be used for...

Page 28: ...stallation Please consult your retailer or dealer for assistance NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors The NIGH...

Page 29: ...ll operating If the unit in Room A enters POWERFUL operation operation capacity will be concentrated in Room A In such a case the cooling heating efficiency of the units in Rooms B C and D may be slig...

Page 30: ...e front panel into the slots and push them in all the way Close the front panel slowly and push the panel at the 3 points 1 on each side and 1 in the middle CAUTION Units Don t touch the metal parts o...

Page 31: ...h them with neutral detergent thinned with lukewarm water then dry them up in the shade It is recommended to clean the air filters every 2 weeks Titanium Apatite Photocatalytic Air Purifying Filter Th...

Page 32: ...er contact to the service shop there you bought the air conditioner Dispose of the old filter as non flammable waste Check that the base stand and other fittings of the outdoor unit are not decayed or...

Page 33: ...ring defrost operation The indoor unit gives out odour This happens when smells of the room furniture or cigarettes are absorbed into the unit and discharged with the airflow If this happens we recomm...

Page 34: ...for a moment and check again that the lamps are normal If the lamps stop flashing after the above steps there is no malfunction page 27 An abnormal functioning happens during operation The air condit...

Page 35: ...e environment and human health Please contact the installer or local authority for more information Batteries must be removed from the remote controller and disposed of separately in accordance with r...

Page 36: ...TEMPERATURE SENSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8...

Page 37: ...P IN OPERATING UNIT OR STAND BY UNIT FAULTY COMPRESSOR START INPUT OVERCURRENT HIGH TEMPERATURE SWITCHBOX HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK LOW VOLTAGE TO MAIN CIRCUIT OR MOMENTARY VOLTAGE...

Page 38: ...0711 HT 3P207037 1B M07B014A Two dimensional bar code is a code for manufacturing...