<Weight table> (Hydraulic oil is not included)
Model
SUT10D80L07
SUT16D80L21
Tank capacity
100 L
160 L
Weight
135 kg
145 kg
Precautions for installation
Securing air intake/exhaust space
Do not place an obstacle that blocks the oil cooler's air intake or air exhaust within 10 cm from the unit end
surface.
Install the unit in a well-ventilated place to prevent the area around the unit from being stuffed with hot air.
Make sure that the intake air temperature does not exceed the specified ambient temperature range (35 C or
lower temperature).
WARNING
If the hydraulic unit is used in a place without an air intake/exhaust space, or a place stuffed with hot air,
the oil cooler/AC fan heat exchanging function will deteriorate, causing the hydraulic oil and equipment
to become extremely hot.
If you accidentally touch the hot parts, you may get burns.
CAUTION
If the hydraulic unit is used in a place without an air intake/exhaust space, or where hot air is stuffed
around the unit, the motor and controller become hot, causing the equipment service life to be
remarkably shortened.
When the motor or controller becomes hot, the temperature protection function is activated to stop
operation.
(When the motor or controller becomes extremely hot, the alarm/warning signal will be output.)
If the hydraulic unit is continuously used at a high temperature, the hydraulic equipment (pump, valves,
etc.) will have defects or shortened service life, as well as the electric components described above.
Using the hydraulic unit at a high temperature accelerates deterioration of the hydraulic oil, resulting in
shortened service life.
10 cm or more
Exhaust
Exhaust
Air
intake
10 cm or more
10 cm or more
10 cm or more
Exhaust
Air
intake