PIM-00004
△
1
[Operation Manual]
30/61
DAIKIN INDUSTRIES, LTD.
[11. Operation Panel Operating Procedure]
This hydraulic unit enables you to monitor or change pressure, flow rate or other parameter settings by
operating the controller key switches.
Outline of functions
The operation panel is comprised of the 3-digit LED
, mode key
, setting keys
and
ENT key
. Normally, the panel shows an actual pressure value. It can be switched between the monitor
display mode and set value display mode through key operations.
Description on individual modes
Normal mode: Displays an actual pressure value or alarm code.
Monitor mode: Displays a pressure switch set value, pressure set value, flow rate set value, actual flow rate,
and actual rpm.
Setting mode: Used to set or change a parameter such as pressure and flow rate.
Alarm mode: Alarm records can be checked.
Shift between individual modes
Key switch operations for shift between individual modes are shown below:
3-digit LED
key
(ENT key)
key
(MODE key)
key
(Setting keys)
Power-ON
Normal mode
Monitor mode
Setting mode
Alarm mode
Press
Press
Press
Press
Keep pressing
and
simultaneously for at least two seconds.
Keep pressing
and
simultaneously for at least two seconds.