To keep the motor pump performance in good conditions for a long period, conduct periodic maintenance on
the following items. If there is a problem, repair or replace defective parts.
Standard inspection cycles are listed below. However, these cycles considerably vary depending on the
operating conditions and environment.
Periodic inspection
Item
Inspection cycle
Method
Oil tank
Oil level check
Daily, Occasionally
Make sure that the float of the oil level gauge is between the red and
yellow lines. Check the hydraulic oil for whitish muddiness and air
bubbles.
Oil temperature check
Daily, Occasionally
Make sure that the oil temperature is 60 C or less.
(Normally, use the oil at 15 to 50 C.)
Oil color check
Semiannually
Deterioration of hydraulic oil can be checked by color. If the hydraulic oil
turns brownish (ASTM L4 level: bright yellow), replace it.
Return filter
Daily, Occasionally
Check the indicator for clogging of the return filter.
If the return filter is clogged, replace the filter element.
Oil cooler
AC fan rotation
Daily, Occasionally
Make sure that the AC fan is rotating.
Clogging of the core
Semiannually
Visually check the core for clogging.
If the AC fan rotation is stopped, or the core is clogged,
[1] the oil cooler cooling capacity remarkably deteriorates. This causes
the hydraulic oil or the unit to become hot, resulting in burns. Also,
this accelerates deterioration of the hydraulic oil, causing the unit
service life to be shortened.
[2] the motor becomes hot, causing the motor service life to be
shortened.
[3] the controller heat radiation performance deteriorates, causing the
electric component service life to be shortened.
Pressure display
Operation check
Daily, Occasionally
Check if the indicated value changes according to load condition changes.
Pressure display check
Daily, Occasionally
Make sure that the pressure display for D.H. conforms to the preset value.
Sound and vibration
Daily, Occasionally
Check for abnormal sound and vibration.
Electric wiring
Semiannually
[1] Check the cable sheathing for cracks or fracture.
[2] Measure the insulation resistance, and check for a decrease in
insulation resistance.
[3] Make sure that the ground cable is securely connected.
Hose
Yearly
Check the hose for cracks, fracture or flaws.
Screws and pipes
Daily, Occasionally
Check screws and pipes for looseness and oil leak.