T Sense Keypad Quick User & Installer Manual                                                       Rev 2.0 

 

 

 

 

CLEAR ALARM MEMORY 

 

COMMAND 

INFORMATION 

▪   Press & hold button [6] for 2 seconds 

▪   Clear Zones, Strobe Light  & Ext Comm. Error  

 

DOOR CHIME 
 

COMMAND 

▪   

Hold [7] for 2 sec + [Zone number 01 to 16] + [#]

 

REMARKS  

-When door chime is activated, the keypad will sound each time the designed zone is triggered 

 

SYSTEM SERVICE 

 

COMMAND 

INFORMATION 

▪   Press & hold button [8] for 2 seconds 
 
 
 
 
 
▪   Press the corresponding number to check the trouble 
▪   Press [*] to Exit 

 

Zone 1 (AC Power Loss) 

 

Zone 2 (Low Battery) 

 

Zone 3 (External Communication Failure) 

 

Zone 4 (Telephone Line Loss) 

 

Zone 5 (Tamper Zone) 
 

REMARKS 

Trouble LED (RED)

 is 

ON 

when there is system trouble 

Trouble LED

 is 

OFF

 when there is no system trouble 

 
BYPASS ZONE AND RESTORED 

 

BYPASS 

ZONE RESTORE 

▪  Press & hold button [9] for 2 seconds 
▪  Press [Zone Number] 
▪  Press  [#] to save and exit 

Press [01] to [16] to select zone 1 to 16 
Key in 2 digit 

▪  Press & hold button [9] for 2 seconds 
▪  Press [Zone Number] 
▪  Press  [#] to save and exit 

Press [01] to [16] to select zone 1 to 16 
Key in 2 digit

 

REMARKS  

- Press

 [01] 

to 

[16] 

to select zone 1 to 16

 

again in this menu in order to have quick 

BYPASS

 and 

ZONE RESTORE 

In the normal mode, bypass zone will blinking to show that zone is already bypass. 

-

 Bypass zones are cleared after system is disarmed. 

 
KEY LOCK 
 

COMMAND 

 

[COM] + [1] + [#]

 

REMARKS 
-Key lock is design to avoid miss control by guest or kids.  
- The “Key lock” icon on LCD will turn ON to indicate key lock is enabled and toggle based

 

PRECAUTION 
-If user key in wrong password for 10x,the keypad will automatically lock by itself for 3 minutes 

 
 

SERVICE 

1 2 3 4 5  

Summary of Contents for T Sense AX1

Page 1: ...Security Home Automation System QUICK USER INSTALLER MANUAL REVISION 2 0 ...

Page 2: ...r partition 2 Night Press hold button 3 for 2 seconds If enable Partition Option Press 1 or 2 Press 1 for partition 1 Press 2 for partition 2 Force Press hold button 4 for 2 seconds If enable Partition Option Press 1 or 2 Press 1 for partition 1 Press 2 for partition 2 REMARKS Default Master PIN 111111 The ARMED LED RED is ON if the system is armed ENABLE PARTITION OPTION Steps to Enable Partition...

Page 3: ... is no system trouble BYPASS ZONE AND RESTORED BYPASS ZONE RESTORE Press hold button 9 for 2 seconds Press Zone Number Press to save and exit Press 01 to 16 to select zone 1 to 16 Key in 2 digit Press hold button 9 for 2 seconds Press Zone Number Press to save and exit Press 01 to 16 to select zone 1 to 16 Key in 2 digit REMARKS Press 01 to 16 to select zone 1 to 16 again in this menu in order to ...

Page 4: ...Bell Test Press and Hold for 2sec for BELL CMS Test Press and Hold for 2 sec for CMS Battery Test Press and Hold for 2sec for BATT Identification Test Press and Hold for 2 sec for IDEN Remark Please refer to the identification test table IDENTIFICATION TEST TABLE to scroll System Identification and IO Identification System Identification IO Identification Zone number Description Zone number Descri...

Page 5: ... Clock for Timer for Clock Set Time Program Arm Timer for Timer for Arm Set Time Select Partition Program Disarm Timer for Timer for Disarm Set Time Select Partition Remark Select Partition Refer to Program Arm Disarm Timer User need to enable partition option to select partition The steps as below Press for 2 sec for Partition Opt Press 1 to toggle Delete Arm Timer for Timer for Arm 0 Delete Disa...

Page 6: ...igned as silent Zone Remark Based on Zone Type Setting s Table Refer above table Press the number to toggle the setting Alarm Delay Setting 07 ENTRY1 Partition 1 Entry Delay Timer From 0 to 200 seconds 030 08 ENTRY2 Partition 2 Entry Delay Timer From 0 to 200 seconds 000 09 EXIT1 Partition 1 Exit Delay Timer From 0 to 200 seconds 060 10 EXIT2 Partition 2 Exit Delay Timer From 0 to 200 seconds 000 ...

Page 7: ...Zone 1 ON mean enable Keypad Alarm Reporting x x x x x x x x x x x x x x Zone 2 ON mean enable System Status Combination of function below A System Status B Open Report C Close Report D System Reset Report E CMS Periodic Report Proceed to 39 to set CMS Periodic Test G Alarm Restore Reporting H Bypass Bypass Restore Reporting 34 ZN RPT Zone Alarm Reporting Zone number ON mean enable Alarm Reporting...

Page 8: ... X X X Zone 2 ON mean Tamper activated 24 hours else activate during Arm Zone 3 ON mean Tamper is NC type else NO Remark Keyswitch and Tamper Setting sTable Refer above table Press the number to toggle the setting Programmable Output Setting 54 OC1 OC1 setting Zone 1 ON mean enable OC1 X X X X X X X X X X Zone 2 ON mean enable OC1 with latch high output X X X X X X X X X X Zone 3 ON mean enable OC...

Page 9: ...X X Zone 5 ON mean enable OC4 with momentary low output X X X X X X X X X X Zone 6 ON mean OC4 activated in alarm mode else arm disarm mode X X X X X X X X X X Zone 2 to zone 5 will toggle X X X X X X X X X X Home Automation Setting 64 ET ZN1 Event Trigger Zone Group 1 Zone LED ON mean the zone is will turn on Event Trigger Output when violated 65 ET IO1 Event Trigger Output Group 1 Zone LED ON me...

Reviews: