USER PROGRAMMING SUMMARY 

                

Default Master Pin 111 111

 

Description 

Command 

Enter User Programming Mode 

[Master Pin] + [COM] + [#] 

Exit User Programming Mode 

Press and Hold [*] for 2 sec 

Edit Master Pin 

[

 for Pin] + [#] + [

 for Master] + [#] + [New Pin] + [#]  + [Re-enter Pin] + [#] 

*Edit User 1 - 7 Pin 

[

 for Pin] + [#] + [

 for User 1 - 7] + [#] + [New Pin] + [#]  + [Re-enter Pin] + [#] + 

[Access Level] + [#] + [Partition] + [#] 

*Edit Guest Pin 

[

 for Pin] + [#] + [

 for Guest] + [#] + [New Pin] + [#]  + [Re-enter Pin] + [#] + 

[Access Level] + [#] + [Partition] + [#] + [Valid Day] + [#] 

Remark  [Access Level] – Refer to create/edit User 1 – 7 Pin, Guest/Duress Pin 

Authority for user code can be set according to details below: 
Key [1] – Arm Enable (1)/ Disable (0)

Key [2] – Disarm Enable (1)/ Disable (0)

 

Key [3] – Bypass Enable (1)/ Disable (0), Key [4] – Open/ Close Report (1)/ Disable (0)  

Edit Duress Pin 

[

 for Pin] + [#] + [

 for Duress] + [#] + [4 digit New Pin] + [#] + [Re-enter NEW PIN] 

+ [#] 

Program Clock 

[

 for Timer] + [#] + [

 for Clock] + [#] + [Set Time] + [#] 

**Program Arm Timer 

[

 for Timer] + [#] + [

 for Arm] + [#] + [Set Time] + [#] + [Select Partition] + [#] 

**Program Disarm Timer 

[

 for Timer] + [#] + [

 for Disarm] + [#] + [Set Time] + [#]  + [Select Partition] + [#] 

**

Remark  [Select Partition] – Refer to Program Arm/Disarm Timer 

User need to enable partition option to select partition. The steps as below: 
Press [

] for 2 sec + [

 for Partition Opt] + [Press 1 to toggle] + [#]

 

Delete Arm Timer 

[

 for Timer] + [#] + [

 for Arm] + [#] + [0] + [#] 

Delete Disarm Timer 

[

 for Timer] + [#] + [

 for Disarm] + [#] + [0] + [#] 

Program ON IO Timer  

[

 for Timer] + [#] + [

 for IO On 1 - 4] + [#] + [Set Time] + [#] + [Output] + [#] 

Program OFF IO Timer  

[

 for Timer] + [#] + [

 for IO Off 1 - 4] + [#] + [Set Time] + [#] + [Output] + [#] 

Delete ON IO Timer  

[

 for Timer] + [#] + [

 for IO On 1 - 4] + [#] + [0] + [#] 

Delete OFF IO Timer  

[

 for Timer] + [#] + [

 for IO Off 1 - 4] + [#] + [0] + [#] 

Program Personal Telephone 
Number 

[

 for Phone] + [#] + [

 for Phone 1 - 4] + [#] + [Telephone Number] + [#] 

Delete Personal Telephone 
Number 

[

 for Phone] + [#] + [

 for Phone 1 - 4] + [#] + [0] + [#] 

Installer Access Setting 

[

 for Extra] + [#] + [

 for Ins Ac] + [#] + [Press 1 to toggle] + [#] 

Phone Line Loss Detection Setting 

[

 for Extra] + [#] + [

 for Ph Det] + [#] + [Press 1 to toggle] + [#] 

PC Communication Setting 

[

 for Extra] + [#] + [

 for PC Com] + [#] + [Press 1 to toggle] + [#] 

 

Summary of Contents for T Sense AX1

Page 1: ...Security Home Automation System QUICK USER INSTALLER MANUAL REVISION 2 0 ...

Page 2: ...r partition 2 Night Press hold button 3 for 2 seconds If enable Partition Option Press 1 or 2 Press 1 for partition 1 Press 2 for partition 2 Force Press hold button 4 for 2 seconds If enable Partition Option Press 1 or 2 Press 1 for partition 1 Press 2 for partition 2 REMARKS Default Master PIN 111111 The ARMED LED RED is ON if the system is armed ENABLE PARTITION OPTION Steps to Enable Partition...

Page 3: ... is no system trouble BYPASS ZONE AND RESTORED BYPASS ZONE RESTORE Press hold button 9 for 2 seconds Press Zone Number Press to save and exit Press 01 to 16 to select zone 1 to 16 Key in 2 digit Press hold button 9 for 2 seconds Press Zone Number Press to save and exit Press 01 to 16 to select zone 1 to 16 Key in 2 digit REMARKS Press 01 to 16 to select zone 1 to 16 again in this menu in order to ...

Page 4: ...Bell Test Press and Hold for 2sec for BELL CMS Test Press and Hold for 2 sec for CMS Battery Test Press and Hold for 2sec for BATT Identification Test Press and Hold for 2 sec for IDEN Remark Please refer to the identification test table IDENTIFICATION TEST TABLE to scroll System Identification and IO Identification System Identification IO Identification Zone number Description Zone number Descri...

Page 5: ... Clock for Timer for Clock Set Time Program Arm Timer for Timer for Arm Set Time Select Partition Program Disarm Timer for Timer for Disarm Set Time Select Partition Remark Select Partition Refer to Program Arm Disarm Timer User need to enable partition option to select partition The steps as below Press for 2 sec for Partition Opt Press 1 to toggle Delete Arm Timer for Timer for Arm 0 Delete Disa...

Page 6: ...igned as silent Zone Remark Based on Zone Type Setting s Table Refer above table Press the number to toggle the setting Alarm Delay Setting 07 ENTRY1 Partition 1 Entry Delay Timer From 0 to 200 seconds 030 08 ENTRY2 Partition 2 Entry Delay Timer From 0 to 200 seconds 000 09 EXIT1 Partition 1 Exit Delay Timer From 0 to 200 seconds 060 10 EXIT2 Partition 2 Exit Delay Timer From 0 to 200 seconds 000 ...

Page 7: ...Zone 1 ON mean enable Keypad Alarm Reporting x x x x x x x x x x x x x x Zone 2 ON mean enable System Status Combination of function below A System Status B Open Report C Close Report D System Reset Report E CMS Periodic Report Proceed to 39 to set CMS Periodic Test G Alarm Restore Reporting H Bypass Bypass Restore Reporting 34 ZN RPT Zone Alarm Reporting Zone number ON mean enable Alarm Reporting...

Page 8: ... X X X Zone 2 ON mean Tamper activated 24 hours else activate during Arm Zone 3 ON mean Tamper is NC type else NO Remark Keyswitch and Tamper Setting sTable Refer above table Press the number to toggle the setting Programmable Output Setting 54 OC1 OC1 setting Zone 1 ON mean enable OC1 X X X X X X X X X X Zone 2 ON mean enable OC1 with latch high output X X X X X X X X X X Zone 3 ON mean enable OC...

Page 9: ...X X Zone 5 ON mean enable OC4 with momentary low output X X X X X X X X X X Zone 6 ON mean OC4 activated in alarm mode else arm disarm mode X X X X X X X X X X Zone 2 to zone 5 will toggle X X X X X X X X X X Home Automation Setting 64 ET ZN1 Event Trigger Zone Group 1 Zone LED ON mean the zone is will turn on Event Trigger Output when violated 65 ET IO1 Event Trigger Output Group 1 Zone LED ON me...