Control System
EDMMT712101
74
VAM-HVE/HVLT Series
Other precautions for installation
z
)NSTALLINAPLACEWITHSUFÚCIENTSTRENGTHANDSTABILITY#HECKTHEPRODUCTSPECIÚCATIONSANDWEIGHT
Use hanging bolts for installation. Consider whether the installation site can withstand the weight of the unit. If not, reinforce the unit
WITHAGIRDERORTHELIKETHENINSTALLHANGINGBOLTS)FTHESTRENGTHISINSUFÚCIENTTHEVIBRATIONOFTHEMAINUNITMAYVIBRATEWITHTHE
installation site, transmitting an abnormal noise.
z
5PSIDEDOWNINSTALLATIONANDDIAGONALINSTALLATIONARENOTPOSSIBLEFORMODELSOTHERTHANTHOSESPECIÚEDFORSUCHUSES
z
Be sure to provide a maintenance space and inspection port. Be sure to provide the necessary maintenance space and inspection
port after checking the outline drawing.
z
When moving the unit during or after unpacking, hold the hanging bracket and do not apply force to other parts, especially the piping
REFRIGERANTDRAINAGEWATERSUPPLY ANDDUCTÚTTINGS
z
If the main unit is installed from the ceiling with short hanging bolts, abnormal noise may occur due to vibration with the ceiling.
Provide anti-vibration measures for the hanging bolts. If abnormal noise is generated from the spiral duct connection, change to
AÛEXIBLEDUCT
z
Do not place electrical/electronic devices and other objects that should not get wet under Heat Reclaim Ventilator unit. Outdoor
TEMPERATUREHUMIDITYCONDITIONSLONGOPERATIONATHIGHHUMIDITYORMORE CLOGGEDDRAINOUTLETANDDIRTYAIRÚLTERMAYCAUSE
dews to fall from the Heat Reclaim Ventilator unit, which may result in damages and contaminations.
z
When using a booster fan, do not create a negative pressure inside the SA (supply air) duct. If the pressure becomes negative,
THEWATERWILLNOTBESUFÚCIENTLYDRAINEDDURINGHUMIDIÚCATIONORDEHUMIDIÚCATIONOUTSIDEAIRPROCESSINGTYPEONLY WHICHMAYCAUSE
WATERLEAKAGEORHUMIDIÚCATIONERROR
z
When taking in OA (outside air) using a cool tube, cool pit or the like, do not provide a construction that overcools and exceeds the air
condition of the OA (outside air) relative humidity at the outside air intake port of Heat Reclaim Ventilator unit. Such a construction may
cause water leakage or malfunction of the unit.
Summary of Contents for VAM Series
Page 2: ......
Page 4: ...EDMMT712101 2 Table of Contents 17 6 Precautions for Design and Installation 181 ...
Page 56: ...Control System EDMMT712101 54 VAM HVE HVLT Series C 3P343420 1E ...
Page 138: ...Installation Manual EDMMT712101 136 VAM HVE HVLT Series 3P607378 3C ...
Page 139: ...EDMMT712101 Installation Manual VAM HVE HVLT Series 137 3P607378 3C ...
Page 141: ...EDMMT712101 Installation Manual VAM HVE HVLT Series 139 C EM20A032 ...
Page 142: ...Installation Manual EDMMT712101 140 VAM HVE HVLT Series C EM20A032 ...
Page 143: ...EDMMT712101 Installation Manual VAM HVE HVLT Series 141 C EM20A032 ...
Page 147: ...EDMMT712101 Details of Optional Accessories VAM HVE HVLT Series 145 3P607378 3C ...
Page 148: ...Details of Optional Accessories EDMMT712101 146 VAM HVE HVLT Series 3P607378 3C ...
Page 149: ...EDMMT712101 Details of Optional Accessories VAM HVE HVLT Series 147 3P607378 3C ...
Page 150: ...Details of Optional Accessories EDMMT712101 148 VAM HVE HVLT Series 3P607378 3C ...
Page 151: ...EDMMT712101 Details of Optional Accessories VAM HVE HVLT Series 149 3P607378 3C ...
Page 152: ...Details of Optional Accessories EDMMT712101 150 VAM HVE HVLT Series 3P607378 3C ...
Page 155: ...EDMMT712101 Details of Optional Accessories VAM HVE HVLT Series 153 4P457318 1D ...
Page 156: ...Details of Optional Accessories EDMMT712101 154 VAM HVE HVLT Series 4P457318 1D ...
Page 157: ...EDMMT712101 Details of Optional Accessories VAM HVE HVLT Series 155 4P457318 1D ...
Page 158: ...Details of Optional Accessories EDMMT712101 156 VAM HVE HVLT Series 4P457318 1D ...
Page 159: ...EDMMT712101 Details of Optional Accessories VAM HVE HVLT Series 157 4P457318 1D ...
Page 184: ......
Page 185: ......
Page 186: ......
Page 187: ......