background image

 

FXCQ20~125M7V1B
VRV System air conditioners
4PW15108-1

Installation and operation manual

 

1

 

C

 

ONTENTS

 

Page

 

Before installation .............................................................................. 1

Selecting installation site ................................................................... 2

Preparations before installation ......................................................... 2

Indoor unit installation........................................................................ 2

Refrigerant piping work...................................................................... 3

Drain piping work............................................................................... 3

Electric wiring work............................................................................ 4

Wiring example and how to set the remote controller ....................... 5

Wiring example.................................................................................. 5

Installation of the decoration panel.................................................... 6

Test operation .................................................................................... 6

Maintenance ...................................................................................... 6

Wiring diagram .................................................................................. 8

 

B

 

EFORE

 

 

 

INSTALLATION

 

 

Leave the unit inside its packaging until you reach the
installation site. Where unpacking is unavoidable, use a sling of
soft material or protective plates together with a rope when
lifting, this to avoid damage or scratches to the unit.

 

 

Refer to the installation manual of the outdoor unit for items not
described in this manual.

 

 

Caution concerning refrigerant series R-410A:
The connectable outdoor units must be designed exclusively for
R-410A.

 

Precautions

 

 

Do not install or operate the unit in rooms mentioned below.

Places with mineral oil, or filled with oil vapour or spray like in
kitchens. (Plastic parts may deteriorate.)

Where corrosive gas like sulphurous gas exists. (Copper tubing
and brazed spots may corrode.)

Where volatile flammable gas like thinner or gasoline is used.

Where machines generating electromagnetic waves exist.
(Control system may malfunction.)

Where the air contains high levels of salt such as air near the
ocean and where voltage fluctuates a lot (e.g. in factories). Also
in vehicles or vessels.

 

 

When selecting the installation site, use the supplied paper
pattern for installation.

 

 

Do not install accessories on the casing directly. Drilling holes in the
casing may damage electrical wires and consequently cause fire.

 

Accessories

 

Check if the following accessories are included with your unit.

 

Optional accessories

 

 

There are two types of remote controllers: wired and wireless.
Select a remote controller according to customers request and
install in an appropriate place.
Refer to catalogues and technical literature for selecting a
suitable remote controller.

 

 

Decoration panel.

 

For the following items, take special care during 
construction and check after installation is finished

 

FXCQ20M7V1B

FXCQ50M7V1B

FXCQ25M7V1B

FXCQ63M7V1B

FXCQ32M7V1B

FXCQ80M7V1B

FXCQ40M7V1B

FXCQ125M7V1B

 

VRV System air conditioners

 

Installation

and operation manual

 

READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.

IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.

IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE
AND INFORMATION.

 

Clamp

1 piece

Also used as packing 

material

Paper pattern for 

installation

1 piece

Drain hose

1 piece

Insulation for fitting

1 each

for gas pipe

for liquid pipe

Screws M5

For paper pattern 

for installation

4 pieces

Washer for hanging 

bracket

8 pieces

Other: installation and operation manual

 

Tick 

 

 

 

when 

checked

 

 

Is the indoor unit fixed firmly?

The unit may drop, vibrate or make noise.

 

 

Is the gas leak test finished?

It may result in insufficient cooling.

 

 

Is the unit fully insulated?

Condensate water may drip.

 

 

Does drainage flow smoothly?

Condensate water may drip.

 

 

Does the power supply voltage correspond to that shown on the 
name plate?

The unit may malfunction or components may burn out.

 

 

Are wiring and piping correct?

The unit may malfunction or components may burn out.

 

 

Is the unit safely grounded?

Dangerous at electric leakage.

 

 

Is the wiring size according to specifications?

The unit may malfunction or components may burn out.

 

 

Is nothing blocking the air outlet or inlet of either the indoor or 
outdoor units?

It may result in insufficient cooling.

 

 

Are refrigerant piping length and additional refrigerant charge 
noted down?

The refrigerant charge in the system might not be clear.

Summary of Contents for VRV FXCQ20M7V1B

Page 1: ...INSTALLATION AND OPERATION MANUAL FXCQ20M7V1B FXCQ25M7V1B FXCQ32M7V1B FXCQ40M7V1B FXCQ50M7V1B FXCQ63M7V1B FXCQ80M7V1B FXCQ125M7V1B System air conditioner...

Page 2: ...20 20 C B 2 6 A 7 5 D 1 2 3 4 12 12 1 2 3 4 11 11 5 6 8 7 9 13 12 10 11 3 4 2 1 13 13 P 1 P 2 F 1 F 2 T 1 T 2 8 7 5 6 4 3 1 2 8 8 300 mm 1 15 m 600 290 2 3 4 6 5 1 9 9 100 mm 1 10 10 1 7 5 6 2 3 4 5...

Page 3: ...P2 F1 F2 T1 T2 1 2 3 4 19 19 S M S S M 2 3 1 21 21 SETTING 2 1 4 3 16 16 L N IN D OUT D F1 F2 F1 F2 Control box LN P1 P2 P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1...

Page 4: ...vande dokument under f ruts ttning att anv ndning sker i verensst mmelse med v ra instruktioner respektive utstyr er i overensstemmelse med f lgende standard er eller andre normgivende dokument er und...

Page 5: ...request and install in an appropriate place Refer to catalogues and technical literature for selecting a suitable remote controller Decoration panel For the following items take special care during c...

Page 6: ...8 or M10 size bolt Use anchors for existing ceilings and a sunken insert sunken anchors or other field supplied parts for new ceilings to reinforce the ceiling in order to bear the weight of the unit...

Page 7: ...igerant gas leak A toxic gas may be released by the refrigerant gas leaking indoor and being exposed to flames from an area heater cooking stove etc Table 1 DRAIN PIPING WORK Rig the drain piping as s...

Page 8: ...on manual of the remote controller All wiring must be performed by an authorized electrician A circuit breaker capable of shutting down power supply to the entire system must be installed This system...

Page 9: ...to the terminals Be careful that wires do not place external stress on the terminals Keep wiring in neat order so that they do not obstruct other equipment such as popping open the service cover Make...

Page 10: ...ON OF THE DECORATION PANEL Refer to the installation manual attached to the decoration panel After installing the decoration panel ensure that there is no space between the unit body and decoration pa...

Page 11: ...filters arrow direction facing upward push up along the guide Replace the air filter by performing the filter removal procedure in reverse 5 Shut the air inlet grill Refer to item No 1 6 After turning...

Page 12: ...N OFF BUTTON H1P LIGHT EMITTING DIODE ON RED H2P LIGHT EMITTING DIODE TIMER GREEN H3P LIGHT EMITTING DIODE FILTER SIGN RED H4P LIGHT EMITTING DIODE DEFROST ORANGE SS1 SELECTOR SWITCH MAIN SUB SS2 SELE...

Page 13: ...NOTES NOTES...

Page 14: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN15108 1...