Model Selection
SiBE37-701
6
General Information
4. Model Selection
VRV III Heat Recovery Series
Connectable indoor units number and capacity
Normal Series
HP
8HP
10HP
12HP
14HP
16HP
18HP
20HP
System name
REYQ8P
REYQ10P
REYQ12P
REYQ14P
REYQ16P
REYQ18P
REYQ20P
Outdoor unit 1
REYQ8P
REYQ10P
REYQ12P
REYQ14P
REYQ16P
REMQ8P
REMQ8P
Outdoor unit 2
–
–
–
–
–
REMQ10P
REMQ12P
Outdoor unit 3
–
–
–
–
–
–
–
Total number of connectable
indoor units
13
16
19
22
26
29
32
Total capacity of connectable
indoor units (kW)
10.0~26.0
12.5~32.5
15.0~39.0
17.5~45.5
20.0~52.0
22.5~58.5
25.0~65.0
HP
22HP
24HP
26HP
28HP
30HP
32HP
34HP
System name
REYQ22P
REYQ24P
REYQ26P
REYQ28P
REYQ30P
REYQ32P
REYQ34P
Outdoor unit 1
REMQ10P
REMQ12P
REMQ10P
REMQ12P
REMQ14P
REMQ16P
REMQ8P
Outdoor unit 2
REMQ12P
REMQ12P
REMQ16P
REMQ16P
REMQ16P
REMQ16P
REMQ10P
Outdoor unit 3
–
–
–
–
–
–
REMQ16P
Total number of connectable
indoor units
35
39
42
45
48
52
55
Total capacity of connectable
indoor units (kW)
27.5~71.5
30.0~78.0
32.5~84.5
35.0~91.0
37.5~97.5
40.0~104.0
42.5~110.5
HP
36HP
38HP
40HP
42HP
44HP
46HP
48HP
System name
REYQ36P
REYQ38P
REYQ40P
REYQ42P
REYQ44P
REYQ46P
REYQ48P
Outdoor unit 1
REMQ8P
REMQ10P
REMQ12P
REMQ10P
REMQ12P
REMQ14P
REMQ16P
Outdoor unit 2
REMQ12P
REMQ12P
REMQ12P
REMQ16P
REMQ16P
REMQ16P
REMQ16P
Outdoor unit 3
REMQ16P
REMQ16P
REMQ16P
REMQ16P
REMQ16P
REMQ16P
REMQ16P
Total number of connectable
indoor units
58
61
64
Total capacity of connectable
indoor units (kW)
45.0~117.0
47.5~123.5
50.0~130.0
52.5~136.5
55.0~143.0
57.5~149.5
60.0~156.0
Summary of Contents for VRV III REYQ10PY1B
Page 1: ...REYQ8 48PY1B R 410A Heat Recovery 50Hz SiBE37 701 ...
Page 111: ...Refrigerant Flow for Each Operation Mode SiBE37 701 100 Refrigerant Circuit ...
Page 252: ...SiBE37 701 Troubleshooting by Remote Controller Troubleshooting 241 ...
Page 396: ...SiBE37 701 Piping Diagrams Appendix 385 REYQ14P 16P 3D058153B S2NPL S1NPH ...
Page 397: ...Piping Diagrams SiBE37 701 386 Appendix REMQ8P 3D057743 ...
Page 398: ...SiBE37 701 Piping Diagrams Appendix 387 REMQ10P 12P 3D057742 ...
Page 399: ...Piping Diagrams SiBE37 701 388 Appendix REMQ14P 16P 3D057741 ...
Page 400: ...SiBE37 701 Piping Diagrams Appendix 389 1 2 Indoor Unit FXFQ P ...
Page 405: ...Piping Diagrams SiBE37 701 394 Appendix 1 3 BS Unit 4D057985A ...
Page 415: ...Wiring Diagrams for Reference SiBE37 701 404 Appendix FXZQ20M 25M 32M 40M 50MV1 ...
Page 416: ...SiBE37 701 Wiring Diagrams for Reference Appendix 405 FXCQ20M 25M 32M 63MV3 ...
Page 417: ...Wiring Diagrams for Reference SiBE37 701 406 Appendix FXCQ40M 50M 80M 125MV3 ...
Page 420: ...SiBE37 701 Wiring Diagrams for Reference Appendix 409 FXDQ20M 25MV3 ...
Page 421: ...Wiring Diagrams for Reference SiBE37 701 410 Appendix FXSQ20M 25M 32M 40M 50M 63MV3 ...
Page 422: ...SiBE37 701 Wiring Diagrams for Reference Appendix 411 FXSQ80M 100M 125MV3 ...
Page 447: ...Example of connection SiBE37 701 436 Appendix ...
Page 453: ...Method of Checking the Inverter s Power Transistors and Diode Modules SiBE37 701 442 Appendix ...
Page 467: ...SiBE37 701 iv Index ...