SiBE37-701
Specifications
Specifications
23
Roundflow Ceiling Mounted Cassette
1-1 TECHNICAL SPECIFICATIONS
FXFQ63PVEB
FXFQ80PVEB
FXFQ100PVEB
FXFQ125PVEB
Piping
connections
Liquid
(OD)
Type
Flare connection
Diameter
mm
9.5
9.5
9.5
9.5
Gas
Type
Flare connection
Diameter
mm
15.9
15.9
15.9
15.9
Drain
Diameter
mm
VP25 (I.D. 25/O.D. 32)
Heat Insulation
Foamed polystyrene/polyethylene
Sound absorbing insulation
(Foamed Polyurethane)
Decoration
Panel
Model
BYCQ140CW1
Colour
RAL9010
Dimensions Height
mm
50
50
50
50
Width
mm
950
950
950
950
Depth
mm
950
950
950
950
Weight
kg
5.5
5.5
5.5
5.5
Air Filter
Resin net with mold resistance
Standard
Accessories
Standard Accessories
Installation and operation manual
Drain hose
Washer for hanging bracket
Screws
Sealing Pads
Insulation for fitting
Clamp for drain hose
Installation guide
Drain sealing pad
Notes
The sound pressure values are mentioned for a unit installed with rear suction
The sound power level is an absolute value indicating the power wich a sound source generates.
Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35°CDB,
equivalent refrigerant piping : 5m, level difference : 0m.
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB,
equivalent refrigerant piping : 5m (horizontal)
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
Summary of Contents for VRV III REYQ8PY1B
Page 1: ...REYQ8 48PY1B R 410A Heat Recovery 50Hz SiBE37 701...
Page 111: ...Refrigerant Flow for Each Operation Mode SiBE37 701 100 Refrigerant Circuit...
Page 252: ...SiBE37 701 Troubleshooting by Remote Controller Troubleshooting 241...
Page 396: ...SiBE37 701 Piping Diagrams Appendix 385 REYQ14P 16P 3D058153B S2NPL S1NPH...
Page 397: ...Piping Diagrams SiBE37 701 386 Appendix REMQ8P 3D057743...
Page 398: ...SiBE37 701 Piping Diagrams Appendix 387 REMQ10P 12P 3D057742...
Page 399: ...Piping Diagrams SiBE37 701 388 Appendix REMQ14P 16P 3D057741...
Page 400: ...SiBE37 701 Piping Diagrams Appendix 389 1 2 Indoor Unit FXFQ P...
Page 405: ...Piping Diagrams SiBE37 701 394 Appendix 1 3 BS Unit 4D057985A...
Page 415: ...Wiring Diagrams for Reference SiBE37 701 404 Appendix FXZQ20M 25M 32M 40M 50MV1...
Page 416: ...SiBE37 701 Wiring Diagrams for Reference Appendix 405 FXCQ20M 25M 32M 63MV3...
Page 417: ...Wiring Diagrams for Reference SiBE37 701 406 Appendix FXCQ40M 50M 80M 125MV3...
Page 420: ...SiBE37 701 Wiring Diagrams for Reference Appendix 409 FXDQ20M 25MV3...
Page 421: ...Wiring Diagrams for Reference SiBE37 701 410 Appendix FXSQ20M 25M 32M 40M 50M 63MV3...
Page 422: ...SiBE37 701 Wiring Diagrams for Reference Appendix 411 FXSQ80M 100M 125MV3...
Page 447: ...Example of connection SiBE37 701 436 Appendix...
Page 453: ...Method of Checking the Inverter s Power Transistors and Diode Modules SiBE37 701 442 Appendix...
Page 467: ...SiBE37 701 iv Index...