Troubleshooting by Indication on the Remote Controller
SiUS34-907
148
Troubleshooting
3.23
“
J5
”
Malfunction of Thermistor (R3T, R5T) for Suction Pipe
1, 2
Remote
Controller
Display
J5
Applicable
Models
RXYMQ36 · 48PVJU
Method of
Malfunction
Detection
Malfunction is detected from the temperature detected by the thermistor for suction pipe 1, 2.
Malfunction
Decision
Conditions
When a short circuit or an open circuit in the thermistor for suction pipe 1, 2 are detected
Supposed
Causes
Defect of thermistor (R3T or R5T) for outdoor unit suction pipe
Defect of outdoor unit PCB (A1P)
Defect of thermistor connection
Troubleshooting
∗
Refer to “Thermistor Resistance / Temperature Characteristics” table on P.241.
Replace the thermistor (R3T or
R5T).
Resistance
is normal
w
hen
meas
u
red after disconnecting
the thermistor (R3T or R5T)
from the o
u
tdoor
u
nit PCB.
(3.5k
W
to
360k
W
)
Connector is
connected to X12A of o
u
tdoor
u
nit PCB. (A1P)
Replace the o
u
tdoor
u
nit PCB
(A1P).
N
O
Connect the connector and t
u
rn
on again.
N
O
YES
Caution
Be s
u
re to t
u
rn off the po
w
er s
w
itch
b
efore connecting or disconnecting the connector, or parts may
b
e damaged.
Confirm
w
hich thermistor is a
b
normal
u
sing o
u
tdoor
u
nit "monitor mode".
(Refer to P.105, 106)
YES
Summary of Contents for VRV III-S RXYMQ36 48PVJU
Page 1: ...RXYMQ36 48PVJU R 410A Heat Pump 60Hz SiUS34 907...
Page 9: ...SiUS34 907 Safety Considerations viii...
Page 237: ...Wiring Diagrams SiUS34 907 228 Appendix 2 2 Field Wiring RXYMQ36 48PVJU 3D065370...
Page 238: ...SiUS34 907 Wiring Diagrams Appendix 229 2 3 Indoor Unit FXFQ12M 18M 24M 30M 36MVJU 3D042620C...
Page 239: ...Wiring Diagrams SiUS34 907 230 Appendix FXZQ07M 09M 12M 18MVJU 3D059263...
Page 240: ...SiUS34 907 Wiring Diagrams Appendix 231 FXDQ07M 09M 12M 18M 24MVJU 3D050501A...
Page 241: ...Wiring Diagrams SiUS34 907 232 Appendix FXMQ07P 09P 12P 18P 24P 30P 36P 48PVJU 3D065984A...
Page 242: ...SiUS34 907 Wiring Diagrams Appendix 233 FXHQ12M 24M 36MVJU 3D048116A...
Page 243: ...Wiring Diagrams SiUS34 907 234 Appendix FXAQ07M 09M 12M 18M 24MVJU 3D046039D...
Page 244: ...SiUS34 907 Wiring Diagrams Appendix 235 FXLQ12M 18M 24MVJU FXNQ12M 18M 24MVJU 3D045644A...
Page 247: ...Option List SiUS34 907 238 Appendix...
Page 249: ...Example of Connection 240...
Page 263: ...Precautions for New Refrigerant R 410A SiUS34 907 254 Precautions for New Refrigerant R 410A...