1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user’s manual carefully before using this product. The user’s manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any inquiries, please contact your local importer, distributor and/or retailer.
©All rights reserved 02/20 FS
●
Specifications, designs and other content appearing in this brochure are current as of February 2020 but subject to change without notice.
EDUS371704C-D
ENGINEERING DATA
VRV
REYQ-TATJA, 208/230 V • REYQ-TAYDA, 460 V HEAT RECOVERY 60 Hz DESIGN MANUAL
Summary of Contents for VRV IV REYQ72TATJA
Page 2: ......
Page 34: ...32 REYQ TATJA TAYDA EDUS371704C D 10 Dimensions REYQ72TATJA TAYDA 3D090838C...
Page 41: ...39 REYQ TATJA TAYDA EDUS371704C D 12 Center of Gravity REYQ72TATJA 4D090825A...
Page 42: ...40 REYQ TATJA TAYDA EDUS371704C D REYQ96 120TATJA 4D090826A...
Page 43: ...41 REYQ TATJA TAYDA EDUS371704C D REYQ144 168TATJA 4D090827A...
Page 44: ...42 REYQ TATJA TAYDA EDUS371704C D REYQ72TAYDA 4D090828A...
Page 45: ...43 REYQ TATJA TAYDA EDUS371704C D REYQ96 120TAYDA 4D090829A...
Page 46: ...44 REYQ TATJA TAYDA EDUS371704C D REYQ144 168TAYDA 4D090830A...
Page 48: ...46 REYQ TATJA TAYDA EDUS371704C D 14 Piping Diagrams REYQ72TATJA TAYDA 3D091128B...
Page 49: ...47 REYQ TATJA TAYDA EDUS371704C D REYQ96 168TATJA TAYDA 3D091127B...
Page 67: ...65 REYQ TATJA TAYDA EDUS371704C D 18 Operation Limits REYQ72 456TATJA TAYDA 3D091329A...
Page 69: ...67 REYQ TATJA TAYDA EDUS371704C D 20 Sound Levels Reference Data REYQ72TATJA TAYDA C 4D093380A...
Page 70: ...68 REYQ TATJA TAYDA EDUS371704C D REYQ96 120TATJA TAYDA C 4D093379A...
Page 71: ...69 REYQ TATJA TAYDA EDUS371704C D REYQ144 168TATJA TAYDA C 4D093378A...
Page 80: ...78 REYQ TATJA TAYDA EDUS371704C D 2P385982 1A...
Page 81: ...79 REYQ TATJA TAYDA EDUS371704C D Collective Indications Label 3P385986 1A...
Page 82: ...80 REYQ TATJA TAYDA EDUS371704C D 3P385986 1A...
Page 83: ...81 REYQ TATJA TAYDA EDUS371704C D 23 2 REYQ96 168TATJA TAYDA Operation Name Plate 3P385983 1B...
Page 84: ...82 REYQ TATJA TAYDA EDUS371704C D 3P385983 1B...
Page 85: ...83 REYQ TATJA TAYDA EDUS371704C D 1P385984 1A...
Page 86: ...84 REYQ TATJA TAYDA EDUS371704C D 1P385984 1A...
Page 87: ...85 REYQ TATJA TAYDA EDUS371704C D 1P385984 1A...
Page 88: ...86 REYQ TATJA TAYDA EDUS371704C D 1P385984 1A...
Page 89: ...87 REYQ TATJA TAYDA EDUS371704C D 1P385984 1A...
Page 90: ...88 REYQ TATJA TAYDA EDUS371704C D 1P385984 1A...
Page 91: ...89 REYQ TATJA TAYDA EDUS371704C D Collective Indications Label 3P385987 1A...
Page 92: ...90 REYQ TATJA TAYDA EDUS371704C D 3P385987 1A...
Page 103: ......