Installation Manual
EDUS341411-N
10
Installation of Outdoor Units
3P362438-1B
3P362438-1B English
ii
CAUTION
r &QPQVVQWEJVJGUYKVEJYKVJYGVƂPIGTU6QWEJKPICUYKVEJ
YKVJYGVƂPIGTUOC[TGUWNVKPGNGEVTKEUJQEM
r
Do not allow children to play on or around the unit or it
may result in injury.
r 6JGJGCVGZEJCPIGTƂPUCTGUJCTRGPQWIJVQEWVCPF
may result in injury if improperly used. To avoid injury wear
INQXGQTEQXGTVJGƂPUYJGPYQTMKPICTQWPFVJGO
r
Do not touch the refrigerant pipes during and immediately
after operation as the refrigerant pipes may be hot or
EQNFFGRGPFKPIQPVJGEQPFKVKQPQHVJGTGHTKIGTCPVƃQY
-
ing through the refrigerant piping, compressor, and other
refrigerant cycle parts. It may result in your hands get-
ting burns or frostbite if you touch the refrigerant pipes.
To avoid injury, give the pipes time to return to normal
temperature or, if you must touch them, be sure to wear
proper gloves.
r
Install drain piping to proper drainage. Improper drain pip-
ing may result in water leakage and property damage.
r
Insulate piping to prevent condensation.
r
Be careful when transporting the product.
r
Do not turn off the power immediately after stopping
operation. Always wait for at least 5 minutes before turning
off the power. Otherwise, water leakage may result.
r
Do not use a charging cylinder. Using a charging cylinder
may cause the refrigerant to deteriorate.
r
Refrigerant R410A in the system must be kept clean, dry,
and tight.
(a) Clean and Dry - Foreign materials (including mineral
oils such as SUNISO oil or moisture) should be pre-
vented from getting into the system.
(b) Tight - R410A does not contain any chlorine, does
not destroy the ozone layer, and does not reduce the
earth’s protection again harmful ultraviolet radiation.
R410A can contribute to the greenhouse effect if it is
released. Therefore take proper measures to check
for the tightness of the refrigerant piping installation.
Read the chapter Refrigerant Piping and follow the
procedures.
r
Since R410A is a blend, the required additional refriger-
ant must be charged in its liquid state. If the refrigerant is
charged in a state of gas, its composition can change and
the system will not work properly.
r
The indoor unit is for R410A. See the catalog for indoor
models that can be connected. Normal operation is not
possible when connected to other units.
r
Remote controller (wireless kit) transmitting distance can
DGUJQTVGTVJCPGZRGEVGFKPTQQOUYKVJGNGEVTQPKEƃWQTGU
-
cent lamps (inverter or rapid start types). Install the indoor
WPKVHCTCYC[HTQOƃWQTGUEGPVNCORUCUOWEJCURQUUKDNG
r
Indoor units are for indoor installation only. Outdoor units
can be installed either outdoors or indoors. This unit is for
indoor use.
r
Do not install the air conditioner or heat pump in the fol-
lowing locations:
(a) Where a mineral oil mist or oil spray or vapor is pro-
FWEGFHQTGZCORNGKPCMKVEJGP
Plastic parts may deteriorate and fall off and thus may
result in water leakage.
(b) Where corrosive gas, such as sulfurous acid gas, is
produced.
Corroding copper pipes or soldered parts may result
in refrigerant leakage.
(c) Near machinery emitting electromagnetic waves.
'NGEVTQOCIPGVKEYCXGUOC[FKUVWTDVJGQRGTCVKQPQH
the control system and cause the unit to malfunction.
(d)
9JGTGƃCOOCDNGICUOC[NGCMYJGTGVJGTGKUECT
-
DQPƂDGTQTKIPKVCDNGFWUVUWURGPUKQPKPVJGCKTQT
YJGTGXQNCVKNGƃCOOCDNGUUWEJCUVJKPPGTQTICUQNKPG
are handled. Operating the unit in such conditions
OC[TGUWNVKPCƂTG
r
Take adequate measures to prevent the outdoor unit from
being used as a shelter by small animals. Small animals
making contact with electrical parts may result in malfunc-
VKQPUUOQMGQTƂTG+PUVTWEVVJGEWUVQOGTVQMGGRVJG
area around the unit clean.
NOTE
r
Install the power supply and transmission wires for the in-
FQQTCPFQWVFQQTWPKVUCVNGCUV|HV||OCYC[HTQOVGNG
-
visions or radios to prevent image interference or noise.
&GRGPFKPIQPVJGTCFKQYCXGUCFKUVCPEGQH|HV||O
OC[PQVDGUWHƂEKGPVVQGNKOKPCVGVJGPQKUG
r
Dismantling the unit, treatment of the refrigerant, oil and
additional parts must be done in accordance with the
relevant local, state, and national regulations.
r
Do not use the following tools that are used with con-
ventional refrigerants: gauge manifold, charge hose, gas
NGCMFGVGEVQTTGXGTUGƃQYEJGEMXCNXGTGHTKIGTCPVEJCTIG
base, vacuum gauge, or refrigerant recovery equipment.
r
If the conventional refrigerant and refrigerator oil are
OKZGFKP4#VJGTGHTKIGTCPVTGUWNVKPFGVGTKQTCVKQP
r
This air conditioner or heat pump is an appliance that
should not be accessible to the general public.
r
As design pressure is 478 psi (3.3 MPa), the wall thick-
PGUUQHƂGNFKPUVCNNGFRKRGUUJQWNFDGUGNGEVGFKPCEEQT
-
dance with the relevant local, state, and national regula-
tions.
Codes and Regulations
This product is designed and manufactured to comply with
national codes. Installation in accordance with such codes
and/or prevailing local codes/regulations is the responsibility
of the installer. The manufacturer assumes no responsibility
for equipment installed in violation of any codes or regula-
tions. Rated performance is achieved after 72 hours of opera-
tion.
Summary of Contents for VRV IV RXYQ TYDN Series
Page 1: ...EDUS341411 N Installation...
Page 62: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 63 3P161697D...
Page 66: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 67 C 3P113151C 7 8 1 1 1 8...
Page 67: ...REFNET Joint and Header EDUS341411 N 68 Installation of Outdoor Units KHRP26M73HU 3P185500...
Page 68: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 69 3P185500...
Page 70: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 71 1P218719...
Page 71: ...REFNET Joint and Header EDUS341411 N 72 Installation of Outdoor Units 1P218719...
Page 72: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 73 1P218720...
Page 73: ...REFNET Joint and Header EDUS341411 N 74 Installation of Outdoor Units 1P218720...
Page 75: ...REFNET Joint and Header EDUS341411 N 76 Installation of Outdoor Units 1P280278A...
Page 76: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 77 1P280278A...
Page 77: ...REFNET Joint and Header EDUS341411 N 78 Installation of Outdoor Units 1P280279...
Page 79: ...Caution Label EDUS341411 N 80 Installation of Outdoor Units 2P361359C...
Page 80: ...EDUS341411 N Caution Label Installation of Outdoor Units 81 3P357947A...
Page 81: ...Caution Label EDUS341411 N 82 Installation of Outdoor Units 3P357947A...
Page 83: ...Caution Label EDUS341411 N 84 Installation of Outdoor Units 1P361833B...
Page 84: ...EDUS341411 N Caution Label Installation of Outdoor Units 85 1P361833B...
Page 85: ...Caution Label EDUS341411 N 86 Installation of Outdoor Units 1P361833B...
Page 86: ...EDUS341411 N Caution Label Installation of Outdoor Units 87 1P361833B...
Page 87: ...Caution Label EDUS341411 N 88 Installation of Outdoor Units 1P361833B...
Page 88: ...EDUS341411 N Caution Label Installation of Outdoor Units 89 1P361833B...
Page 89: ...Caution Label EDUS341411 N 90 Installation of Outdoor Units 3P357946A...
Page 90: ...EDUS341411 N Caution Label Installation of Outdoor Units 91 3P357946A...