3
|
Components
Service manual
310
REYQ8~20+REMQ5U7Y1B
VRV IV+ Heat Recovery
ESIE18-15B – 2020.05
b
c
d
c
a
c
c
a
Fan motor cable
b
Tie wrap
c
Screw
d
Fan motor
6
Remove the 4 screws that fix the DC fan motor assembly.
7
Remove the DC fan motor assembly from the unit.
8
To install the DC fan motor assembly, see
308].
To install the DC fan motor assembly
1
Install the DC fan motor assembly in the correct location.
2
Fix the DC fan motor assembly to the unit by tightening the screws.
3
Route the DC fan motor cable.
4
Attach the DC fan motor cable.
5
Install a new tie strap to fix the DC fan motor cable.
6
Connect the DC fan motor connector to the connector on the fan inverter
PCB.
7
Lock the ferrite bead.
8
Install the propeller fan blade assembly, see
308].
To install the propeller fan blade assembly
1
Install the propeller fan blade assembly on the DC fan motor assembly.
CAUTION
Do NOT install a damaged propeller fan blade assembly.
2
Install the axle cover.
3
Install and tighten the screw using an Allen key to fix the propeller fan blade
assembly.