SiE-05C
Wiring Diagrams - Outdoor Unit
Appendix Inverter K Series / PLUS Series
341
1. Wiring Diagrams - Outdoor Unit
1.1
Inverter K Series - cooling only
RSX5KA7W1
(ALARM-WHIT
E
)
TER
MIN
A
L
BO
ARD
X2M
X2M
X2M
T
S
R
tfl
: TERMINAL
SS1
BS5
BS3
BS4
HAP
HWL
X5A
K2R
R1
R2
R1T
tfl
K1M
X2A
PNK
YLW
TER
MIN
A
L
STRIP
VARI
S
TO
R
R4T
PM
M1F
M1C
L1R
K10R
K6R
K5R
MAGNETIC
RELAY
(J1HC)
MAGNETIC
RELAY
(Y3S
)
MAGNETIC
RELAY
(Y2S
)
MAGNETIC
RELAY
(M1F
)
PRESSURE SWI
TCH (HIGH)
F1U
A1P,
A
2P
CR
ANK
CASE
HEATER
CAPACITOR
(MODE,S
E
T,RE
TUR
N,
WIR
ING
CHECK,RESET)
H1P-7P
F5U
DIO
DE M
ODULE
PUSH
B
UTT
ON
SWITCH
DC
CURREN
T
TRANSF
ORMER
REACTO
R
H1P-4P
HAP
SENPH
EARTH
LEAK
DET
E
CTOR
R3T
(SERVI
CE
MONITOR-GR
EEN
) (A2P)
LI
GH
T
EMITTING
DIO
DE
(SERVI
CE
MONITOR-RE
D)
(A2P)
LI
GH
T
EMITTING
DIO
DE
(SERVI
CE
MONITOR-GR
EEN
) (A1P)
LI
GH
T
EMITTING
DIO
DE
(SERVI
CE
MONITOR-OR
ANG
E)
(A1
P
)
LI
GH
T
EMITTING
DIO
DE
PILOT
LAMP
TR
A
NSFORMER
(220-240V/22V)
Y3S
Y2S
MOTOR
(FAN)
PRINTED
CIRCUIT
BOA
RD
INVE
RTER
(A2P
)
K1R,
K2R
HAP
TH
E
RMI
S
TOR
(FIN
) (A2P)
SELE
CTOR
S
WITCH
(C/
H
SELECT
)
PRESSURE
S
ENS
OR
(LOW)
T1R
T1C
TH
E
RMI
S
TOR
(AIR)
(A1P)
V1TR
PRESSURE
S
ENS
OR
(HIGH)
S1PH
X1M
TH
E
RMI
S
TOR
(CO
IL)
TH
E
RMI
S
TOR
(DISCHA
RGE
)
Q1M
SAFETY
DEV
IC
ES
IN
PUT
SS1
PC
PO
WER
CIR
CUIT
SURGE
ARRESTER
K1M
TR
IAC
NOI
S
E FILTER
R1T
Z1-3F
FU
S
E
(250
V
,10A)
J1H
C
HWL
COMPR
ESSOR
CONTAC
TOR
(M1C)
F1S
SD
R1V
SENPL
R1-4
R2T
F1C
DM
C
1R-3R
BS1-5
RESI
S
TO
R
TH
E
RMAL
PROT
E
CTOR
(K
LIXON)
(MF1)
SO
LE
NO
ID
VA
LVE
(IN
JECT
ION
M1C)
SO
LE
NO
ID
VALV
E
(HOT
GAS)
MAGNETIC
RELAY
(A2P
)
K2R,
K3R
FIELD
FUSE
INV
MOTOR
(COMPRESSOR)
TH
E
RMI
S
TOR
(SU
CTIO
N)
R1T
PO
WER
M
ODULE
Z2F
C2R
F1S
C3R
L1R
Z1F
Z3F
K1M
C1R
T1R
PM
A2P
Z2F
A1P
INV
T1R
2TW21126-1B
A2P
X3A
Z3F
X1M
(F2)
(F1)
(F2)
(F1)
(C)
(B)
(A)
indoor
outdoor
3
A1P
X13S
X12S
X8S
X10S
J1HC
SD
XCS
XCS
XCS
XCS
F1U
X8A
Q1M
X10A
X5A
X2A
M1F
K3R
K2R
X7A
ORG
BLK
RED
C1R
WHT
YLW
Y3S
Y2S
R1V
X4A
v
T
S
R3
+
-
R4
+
-
+
-
DM
N
L3
L2
L1
F1C
F5U
N
L3
L2
L1
¨
380-415V
3N 50Hz
BS1
X17A
R3T
tfl
X19A
X16A
R4T
tfl
X20A
BS2
R2T
tfl
R1T
tfl
Z1F
R
F1S
K1M
C3R
C2R
3
M
M1C
W
V
U
RED
WHT
BLK
T1C
X3A
K1R
PC
X1A
L1R
V1TR
K10R
K6R
K5R
RED
WHT
BLK
RED
BLU
outdoor
RSX5K*7W1
S1PH
X4A
X1A
SENPL
X21A
X22A
U
V
W
-
+
1
M
PM
L1,L2,L3 : LIVE
N : NEUTRAL
: PROTECTIVE EARTH (SCREW)
COLORS :
: WIRE CLAMP
: CONNECTOR
CENTRAL REMOTE CON
TROLLER.
MANUAL ATTACHED TO THE CENTRAL REMOTE CONTROLLER, WHEN CONNECTING THE
OUTDOOR-OUTDOOR TRANSMISSION OUTPUTS F1-F2, REFER TO THE INSTALLATION
2. FOR CONNECTION WIRING TO INDOOR-OUTDOOR TRANSMISSION INPUT F1-F2,
1. USE COPPER CONDUCTORS ONLY.
YLW : YELLOW
WHT : WHITE
RED : RED
GRY : GRAY
ORG : ORANGE
PNK : PINK
BLK : BLACK
BLU : BLUE
BRN : BROWN
FIELD WIRING
H1P
H2P
H3P
H4P
H5P
H6P
H7P
H1P
H2P
H3P
H4P
HAP
SENPH
BLU
NOTES
SI-05C.BOOK Page 341 Monday, November 6, 2000 4:13 PM
Все каталоги и инструкции здесь:
http
:
//splitoff.ru/tehn-doc.html