SiE33-102
Test Operation
General Information
91
4.14
Contents of Control Modes
Twenty modes consisting of combinations of the following five operation modes with temperature and
operation mode setting by remote control can be set and displayed by operation modes 0 through 19.
ON/OFF control impossible by remote control
Used when you want to turn on/off by central remote control only.
(Cannot be turned on/off by remote control.)
OFF control only possible by remote control
Used when you want to turn on by central remote control only, and off by remote control only.
Centralized
Used when you want to turn on by central remote control only, and turn on/off freely by remote control
during set time.
Individual
Used when you want to turn on/off by both central remote control and remote control.
Timer operation possible by remote control
Used when you want to turn on/off by remote control during set time and you do not want to start
operation by central remote control when time of system start is programmed.
How to Select
Operation Mode
Whether operation by remote control will be possible or not for turning on/off, controlling temperature or
setting operation mode is selected and decided by the operation mode given on the right edge of the table
below.
Do not select “timer operation possible by remote control” if not using a remote control. Operation by timer
is impossible in this case.
∗
1. Factory setting
ON by remote
control
(Unified ON by
central remote
control)
OFF by remote
control
(Unified OFF by
central remote
control)
Temperature
control by
remote control
Operation mode
setting by
remote control
OFF by
remote
control
Control
mode is "1."
Example
↓
Rejection
↓
Rejection
↓
Rejection
↓
Acceptance
↓
Acceptance
(V1345)
Control mode
Control by remote control
Control
mode
Operation
OFF
Temperature
control
Operation
mode
setting
Unified operation, individual
operation by central remote
control, or operation
controlled by timer
Unified OFF, individual stop
by central remote control, or
timer stop
ON/OFF control
impossible by
remote control
Rejection (Example)
Rejection (Example)
Rejection
(Example)
Rejection
Acceptance
0
Rejection
10
Acceptance
(Example)
Acceptance
(Example)
1(Example)
Rejection
11
OFF control only
possible by remote
control
Acceptance
Rejection
Acceptance
2
Rejection
12
Acceptance
Acceptance
3
Rejection
13
Centralized
Acceptance
Rejection
Acceptance
4
Rejection
14
Acceptance
Acceptance
5
Rejection
15
Individual
Acceptance
Rejection
Acceptance
6
Rejection
16
Acceptance
Acceptance
7
∗
1
Rejection
17
Timer operation
possible by remote
control
Acceptance
(During timer at ON position
only)
Acceptance
(During timer at ON position
only)
Rejection
Acceptance
8
Rejection
18
Acceptance
Acceptance
9
Rejection
19
Si33-102.book Page 91 Tuesday, June 26, 2001 3:18 PM