SiME332106E
Specifications
Part 1 General Information
13
Model name
RXYMQ5AYFK
RXYMQ6AYFK
Power supply
3 phase, 380-415/400 V, 50/60 Hz
3 phase, 380-415/400 V, 50/60 Hz
Cooling capacity at T1
(1)
1
Capacity
kW
14.1
16.0
Capacity
Btu/h
48,000
54,500
EER
kW/kW
3.91
3.90
EER
Btu/W·h
13.35
13.30
PI
kW
3.60
4.10
Cooling capacity at T1
(2)
1
Capacity
kW
14.1
16.0
Capacity
Btu/h
48,000
54,500
EER
kW/kW
3.94
3.94
EER
Btu/W·h
13.45
13.45
PI
kW
3.57
4.05
Cooling capacity at T3
1
Capacity
kW
12.7
14.5
Capacity
Btu/h
43,500
49,500
EER
kW/kW
2.97
2.96
EER
Btu/W·h
10.15
10.10
PI
kW
4.29
4.90
CSPF
3
W/W
5.40
5.35
Power factor
0.9
0.9
Cooling capacity at T4
1
Capacity
kW
11.7
12.9
Capacity
Btu/h
40,000
44,000
EER
kW/kW
2.99
3.00
EER
Btu/W·h
10.20
10.25
PI
kW
3.92
4.29
Heating capacity at H1
1
Capacity
kW
16.0
18.0
Capacity
Btu/h
54,500
61,500
COP
kW/kW
4.35
4.25
COP
Btu/W·h
14.85
14.50
PI
kW
3.67
4.24
Allowed indoor capacity
index connection
Nom.
125
150
Min.
62.5
75
Max.
162.5
195
Dimensions
(H×W×D)
Unit
mm
870×1,100×460
870×1,100×460
Packed unit
mm
1,010×1,190×560
1,010×1,190×560
Mass
Unit
kg
120
120
Packed unit
kg
134
134
Heat
exchanger
Type
Cross fin coil
Cross fin coil
Fan
Type
Propeller
Propeller
Discharge direction
Side
Side
Motor
Quantity
1
1
Model
Brushless DC
Brushless DC
Output/pcs
W
600
600
Airflow
rate
Cooling
m³/min
123
123
Heating
m³/min
145
145
Compressor
Quantity
1
1
Motor
Quantity
1
1
Model
Inverter
Inverter
Type
Hermetically sealed swing type
Hermetically sealed swing type
Refrigerant
Refrigerant name
R-410A
R-410A
Charge
kg
5.4
5.4
Piping
connections
Liquid
Type
Flare connection
Flare connection
Diameter (OD)
mm
9.5
9.5
Gas
Type
Brazing connection
Brazing connection
Diameter (OD)
mm
15.9
19.1
Safety devices
High pressure switch, Fan driver overload protector,
Inverter overload protector, Fuse,
Bimetal thermostat (external overload relay),
Over/under voltage protection PCB
High pressure switch, Fan driver overload protector,
Inverter overload protector, Fuse,
Bimetal thermostat (external overload relay),
Over/under voltage protection PCB
Standard accessories
Installation manuals, Operation manual,
Auxiliary pipe, etc.
Installation manuals, Operation manual,
Auxiliary pipe, etc.
Drawing No.
C: 2D135391B
C: 2D135391B
Notes:
1. The above data are based on the following conditions.
Condition
Indoor DB (°C)
Indoor WB (°C)
Outdoor DB (°C)
Outdoor WB (°C)
Reference standard
T1
(1)
27.0
19.0
35.0
—
ISO 15042:2011
T1
(2)
26.6
19.4
35.0
—
AHRI-1230
T3
29.0
19.0
46.0
—
ISO 15042:2011
T4
26.6
19.4
48.0
—
AHRI-1230
H1
20.0
—
7.0
6.0
ISO 15042:2011
2. For detailed contents, see installation/operational manual.
3. Cooling seasonal performance factor for hot climates at T3 condition as per ISO 16358-1:2013/AMD 1:2019