SiME332106E
Troubleshooting by Error Code
Part 6 Service Diagnosis
195
Note(s)
5.23 Current Leakage Detection
Applicable
Models
RXYMQ4-6AYFK
Error Code
E2
Sub code: 01
Method of Error
Detection
Current leakage is detected in the earth leakage detection circuit. Error is detected on the
outdoor unit main PCB.
Error Decision
Conditions
When leakage current is detected.
Supposed
Causes
Earth fault
Defective wiring with the current sensor
Temporary liquid back or refrigerant stagnation
Troubleshooting
1. M1C
Caution
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Correct the wiring.
Normal
(Keep operating)
It is possibly caused by
temporary oil return or
refrigerant stagnation.
(Perform maintenance
during long-term
shutdown such as a
power outage.)
Check
if the
connection to the
current sensor (T1A) is
correctly wired.
NO
Replace the compressor.
(
1)
Defective compressor
insulation
YES
YES
Replace the corresponding
parts.
Defective
insulation of parts
other than the
compressor
YES
NO
NO
Turn OFF the power supply,
and then disconnect the
compressor lead wire.
Reconnect the wires, and
then reconnect the unit to the
power supply.