SiME332106E
Outline of Control (Indoor Unit)
Part 4 Functions and Control
73
8.4 Airflow Direction Control
8.4.1 Without Optional Infrared Floor Sensor
Refer to the table below for controlling the horizontal flap (or the vertical flap) for airflow direction
adjustment.
8.4.2 With Optional Infrared Floor Sensor
The model can control airflow direction automatically by the difference between suction air
temperature and floor temperature.
Operation in auto airflow direction control when cooling
Operation in auto airflow direction control when heating
Conditions
FXAQ-AR
Cooling
Direction set
Thermostat ON
Set
Thermostat OFF
Set
Swing set
Thermostat ON
Swing
Thermostat OFF
Swing
Program dry
Direction set
Thermostat ON
Set
Thermostat OFF
Set
Swing set
Thermostat ON
Swing
Thermostat OFF
Swing
Heating
Direction set
Thermostat ON
Set
Thermostat OFF
Horizontal (P0)
Swing set
Thermostat ON
Swing
Thermostat OFF
Horizontal (P0)
Fan
Direction set
Set
Swing set
Swing
Conditions
FXFSQ-AR
When airflow direction is set
Automatic airflow rate and eco
full automatic control
Cooling
Direction set
Thermostat ON
Set
Automatic (P0 or P1)
Thermostat OFF
Set
Automatic (P0 or P1)
Swing set
Thermostat ON
Swing
—
Thermostat OFF
Swing
—
Program dry
Direction set
Thermostat ON
Set
Automatic (P0 or P1)
Thermostat OFF
Set
Automatic (P0 or P1)
Swing set
Thermostat ON
Swing
—
Thermostat OFF
Swing
—
Heating
Direction set
Thermostat ON
Set
Automatic (P3 or P4)
Thermostat OFF
Horizontal (P0)
Horizontal (P0)
Swing set
Thermostat ON
Swing
—
Thermostat OFF
Horizontal (P0)
—
Fan
Direction set
Set
Horizontal (P0)
Swing set
Swing
—
P1
P0 (Horizontal)
The difference between suction air
and floor temperatures is small.
The difference between suction air
and floor temperatures is large.
P4 (Downward)
The difference between suction air
and floor temperatures is small.
The difference between suction air
and floor temperatures is large.
P3