5-47
Chapter 5 User Menu
14. Laser Power Measurement
With this function, you can check if the PT-R is properly calibrated at a specific laser
power.
1.
Select
[Laser power measure]
in the user setting selection screen and press
[OK]
. The resolution selection screen appears.
Fig. 5-63 Resolution selection screen
2.
Press the button for the desired measurement resolution and press
[OK]
. The
measurement start confirmation screen appears.
Fig. 5-64 Measurement start confirmation screen
3.
Select
[YES]
and press
[OK]
. The laser power measurement begins.
The measurement will finish after approx. 60 seconds and then the measurement
results screen for channels 0 to 31 will be displayed.
Fig. 5-65 Measurement results screen
OK
YES
NO
ESC
Start OK
OK
ESC
1200
dpi
2000
dpi
R e s o l u t i o n
2400
dpi
4000
dpi
2438
dpi
2540
dpi
0ch
1ch
2ch
3ch
4ch
5ch
6ch
7ch
100%
99%
98%
100%
100%
100%
100%
100%
8ch
9ch
10ch
11ch
12ch
13ch
14ch
15ch
100%
98%
98%
100%
100%
100%
100%
100%
16ch
17ch
18ch
19ch
20ch
21ch
22ch
23ch
100%
98%
98%
100%
100%
100%
100%
100%
24ch
25ch
26ch
27ch
28ch
29ch
30ch
31ch
100%
98%
98%
100%
100%
100%
100%
100%
OK
Summary of Contents for PLATE RITE 4300
Page 10: ...x...
Page 11: ...Chapter 1 Ensuring Safety 1 This chapter gives information necessary for safe use of the PT R...
Page 26: ...PT R4300 USERS MANUAL 1 16 End of Chapter 1...
Page 38: ...PT R4300 USERS MANUAL 3 8 End of Chapter 3...
Page 39: ...This chapter explains the basic procedures for operating the PT R Chapter 4 Basic Operation 4...
Page 60: ...PT R4300 USERS MANUAL 4 22 End of Chapter 4...
Page 61: ...This chapter explains the procedures for setting PT R parameters Chapter 5 User Menu 5...
Page 122: ...PT R4300 USERS MANUAL 5 62 End of Chapter 5...
Page 157: ...This chapter explains this typical PT R problem and the solutions Chapter 8 Jamming 8...
Page 163: ...This chapter gives technical information on the PT R Chapter 9 Technical Information 9...