5-37
Chapter 5 User Menu
9.2 Test Exposure for Simultaneous Adjustment of Laser Power and
Drum Rpm, or Focus and Zoom
The procedure for performing a test exposure for simultaneously adjust the laser
power and drum rpm, or focus and zoom, is explained here.
NOTE
• In the above screen, the values in parentheses above the initial values show the
drum rpm, laser power, focus, and zoom values in the media type selected when
the plate was loaded. Use it as a reference when performing the test exposure.
• The initial value is the first laser power and drum rpm (or focus value and zoom)
used in the test exposure.
• The increment value indicates the amount of the change from the initial value. For
example, if the laser power increment value is set to 10%, output will take place at
increments of 10% from the initial value.
• The count is the number of times the test exposure is to be carried out.
• The exposure start point is the distance from the plate edge to the point where the
test exposure begins. This value is updated (moved to the next possible exposure
position) each time a test exposure ends.
1.
Press the resolution key and select the resolution value. With each press of the
key the setting changes as follows: 1200 dpi
→
2000 dpi
→
2400 dpi
→
4000
dpi
→
2438 dpi
→
2540 dpi
→
1200 dpi.
2.
Enter what you think is the best initial drum rpm (or focus value) and then press
[ENT]
. The highlight will move to the right initial value setting.
OK
2400dpi
ESC
Initial:
Incriment:
Count:
Start Point:
(0.0 ~ 830.0 [mm])
50.0
2.0
10
(700, 75.0)
25
9
0.0
CLR
7
8
9
4
5
6
1
2
3
0
·
—
ENT
[rpm],[%]
[rpm],[%]
650
Resolution key
These keys can also move
the highlighted portion.
Exposure start point
Currently set value
Increment value
Count
Initial value
Input columns:
Left column
➞
drum rpm
Right column
➞
laser power
OK
2400dpi
ESC
Initial:
Incriment:
Count:
Start Point:
(0.0 ~ 830.0 [mm])
4985
20
7
(2280, 6450)
50
8
0.0
CLR
7
8
9
4
5
6
1
2
3
0
·
—
ENT
[puls]
[puls]
2000
Resolution key
These keys can also move
the highlighted portion.
Exposure start point
Input columns:
Left column
➞
focus value
Right column
➞
zoom value
Increment value
Initial value
Currently set value
Count
Fig. 5-49 Test exposure (simultaneous adjustment) setting screen
Summary of Contents for PLATE RITE 4300
Page 10: ...x...
Page 11: ...Chapter 1 Ensuring Safety 1 This chapter gives information necessary for safe use of the PT R...
Page 26: ...PT R4300 USERS MANUAL 1 16 End of Chapter 1...
Page 38: ...PT R4300 USERS MANUAL 3 8 End of Chapter 3...
Page 39: ...This chapter explains the basic procedures for operating the PT R Chapter 4 Basic Operation 4...
Page 60: ...PT R4300 USERS MANUAL 4 22 End of Chapter 4...
Page 61: ...This chapter explains the procedures for setting PT R parameters Chapter 5 User Menu 5...
Page 122: ...PT R4300 USERS MANUAL 5 62 End of Chapter 5...
Page 157: ...This chapter explains this typical PT R problem and the solutions Chapter 8 Jamming 8...
Page 163: ...This chapter gives technical information on the PT R Chapter 9 Technical Information 9...