• Installation to be performed by factory trained service
personnel only.
• For use inside a commercial refrigeration case with
packaged foods only.
• Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
• Before installing, servicing or cleaning unit, switch power
off at the service panel and follow appropriate lock out/tag
out safety procedures
FOR YOUR SAFETY
Read and observe all CAUTIONS and WARNINGS shown
throughout these instructions.
24
24
Volt
BG
Българската версия на инструкциите за инсталаця
и информация за безопасност могат да бъдат
намерени на следния адрес: https://products.
gecurrent.com/eu
CS
Návod k montáží a bezpečnostní informace v češtině
najdete zde: https://products.gecurrent.com/eu
DA
Den danske version af installationsvejledningen og
sikkerhedsoplysninger kan findes på følgende placering:
https://products.gecurrent.com/eu
DE
Die deutsche Version der Installationsanleitung und
Sicherheitsinformationen finden Sie in folgendem
Verzeic: https://products.gecurrent.com/eu
EL
Μπορείτε να βρείτε την ελληνική εκδχή των οδηγιών
νγκατάστασης και των πληροφοριών ασφάλειας στην
εξής τοποθεσία: https://products.gecurrent.com/eu
ES
La versión española de las instrucciones de instalación y
la información sobre seguridad puede encontrarse en la
siguiente ubicación: https://products.gecurrent.com/eu
ET
Eestikeelse paigaldusjuhendi ja ohutusnñuded leiate
aadressilt: https://products.gecurrent.com/eu
FI
Asennusohjeiden ja turvallisuustietojen suomenkielinen
versio löytyy seuraavasta paikasta: https://products.
gecurrent.com/eu
FR
La version française des instructions d’installations
et information de sécurité est disponible à l’adresse
suivante: https://products.gecurrent.com/eu
HR
Hrvatska verzija priručnika za ugradnju i sigurnosnih
informacija nalazi se na sljedečoj lokaciji: https://
products.gecurrent.com/eu
HU
A telepítési útmutató és a biztnosági információk
magyar nyelvű változata az alábbi címen található:
https://products.gecurrent.com/eu
IT
La versione italiana del manuale di installazione e
sicurezza può essere reperita nella seguente sezione:
https://products.gecurrent.com/eu
LT
Lietuvišką diegimo instrukcijos ir saugos informacijos
versiją galima rasti šioje vietoje: https://products.
gecurrent.com/eu
LV
Uzstādīšanas instrukciju un drošības informāciju latviešu
valodā var atrast šeit: https://products.gecurrent.com/eu
NL
De Nederlandse versie van de installatie-instructies en
veiligheidsinformatie kan op de volgende locatie worden
gevonden: https://products.gecurrent.com/eu
PL
Polską wersję instrukcji instalacji oraz informacje
dotyczące bezpieczeństwa można znaleźć w
następującej lokalizacji: https://products.gecurrent.
com/eu
PT
A versão em Português das instruções de instalação e
das informações de segurança pode ser encontrada na
seguinte localização: https://products.gecurrent.com/eu
RO
Versiunea în limba românǎ a instrucţiunilor de instalare
şi a informaţiilor de siguranţǎ pot fi gǎsite la: https://
products.gecurrent.com/eu
SV
Ni hittar den svenska versionen av
installationsanvisningarna och säkerhetsinformationen
på följande plats: https://products.gecurrent.com/eu
SL
Previdnostna opozorila in varnostne informacije so na
zadnji strani vodnika za namestitev. Pred začetkom
namestitve izdelka jih skrbno preberite: https://products.
gecurrent.com/eu
SK
Slovenskú verziu montažnej príručky a bezpečnostnŷch
instrukcií nájdete na nasledujúcej lokalite: https://
products.gecurrent.com/eu
For the latest North American install guides for your product go to: https://products.gecurrent.com/sign-lighting/tetra-max
For the latest European install guides for your product go to: https://products.gecurrent.com/eu
Electrical Requirements
• The power supply must be supplied with 120-277 VAC,
50/60 Hz, and connected to an individual properly grounded
branch circuit, protected by a 15 or 20 ampere circuit breaker
or time delay fuse.
• Wiring must be 2 wire with ground and rated for 75°C (167°F).
• All wiring must be done to NEC or local electrical codes.
PREPARE ELECTRICAL WIRING
Grounding Instructions–Cable Direct
• This lighting system must be connected to a grounded
metal, permanent wiring system, or an equipment grounding
conductor must be run with the circuit conductors and be
connected to the equipment grounding terminal.
Vertical & Horizontal Cases
93077673 100W LED Driver
GELP24-100U-GLX
Installation Guide
DISP105
Immersion
TM
LED Refrigerated Display Lighting
EN
BEFORE YOU BEGIN
Read these instructions completely and carefully.