background image

This product is intended to be used as a lamp control gear that is installed after the mains control switch.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful 

interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD 

complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.

NOTE:

  This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment 

generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be 

required to correct the interference at his own expense.

Connect LED Driver - Output

1

• For retrofit, place LED driver in the location where the ballast was formerly located. 

• Make output (DC) connections as noted below:
Using the wiring diagram in step 3, connect the LED Driver output leads to the LED Light leads using wire connectors or other 

connection method approved for low temperature usage and solid conductors.
For Retrofit: Bundle and safely secure any unused wires by way of approved wire ties and wire connectors.

A

Mount the LED Driver to a grounded metal portion of the door frame, connect the LED driver housing to an existing equipment 

grounding conductor, or run an equipment grounding conductor to the equipment grounding terminal.  Using the wiring diagram in 

step 3, connect the original Line and neutral wires (or Line 1 and Line 2 wires for 277 maximum VAC) to the LED Driver leads using wire 

connectors or other connection method approved for low temperature usage and solid conductors.

•  Make input (AC) connections as noted below.

•  The LED Driver is required to be reliably bonded to the protective ground conductor.

Connect LED Driver - Input

2

B

C

Immersion

TM

 GELP24-100U-GLX Driver

Installation Guide

2

 

UL WARNING / AVERTISSEMENT UL

Risk of electrical shock. Disconnect power before servicing or installing product. LED Retrofit Kit Installation requires knowledge of luminaires electrical systems. 

If not qualified, do not attempt installation. Contact a qualified electrician. Install this kit only in the luminaires that have the construction features and dimensions 

shown in the photographs and/or drawings. 

Risque de choc électrique. Couper le courant avant de réparer ou installer le produit. LED Retrofit Kit d’installation nécessite la connaissance des systèmes 

luminaires électriques. Si vous n’êtes pas qualifié, ne tentez pas l’installation. Contactez un électricien qualifié. Installez ce kit seulement dans les luminaires qui ont les 

caractéristiques de construction et les dimensions figurant sur les photographies et / ou des dessins.

 

WARNING / AVERTISSEMENT

Risk of electrical shock. Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code. 

Risque de choc électrique. S’assurer que les points de raccordements sont scellés pour emplacement humide en employant une méthode permise 

par le NEC ou par le code électrique local.

 

CAUTION / ATTENTION

Risk of injury. While performing installations described, gloves, safety glasses or goggles should be worn. 

Risque de blessure. Lors de l’exécution des installations décrites, des gants, des lunettes de sécurité ou des lunettes de protection doivent être portées.

 

CAUTION / ATTENTION

Risk of injury. Do not overload LED Driver, 60-watts maximum per driver. Do not exceed the LED light bar loading limits specified on the light bar 

installation instructions for a 60W driver. 

Risque de blessure. Ne pas surcharger l’alimentation à DEL. Maximum de 60 watts par alimentation. Ne pas excéder les limites de charge maximale 

des alimentations telles que spécifiées dans les instructions d’installation.

Reviews: