Installation Guide

Daintree

®

 Networked Sensor Adapter (WSA10)

6

6

Operation with ControlScope Manager

Once joined to the ZigBee network, the WSA10 and its 

connected devices are assigned to zones using the Zone and 

Device Configuration page. Notice that each connected input 

is listed as a separate device. The Device ID and Model columns 

include terminal identifiers for each connected device. These 

identifiers are automatic and carry over to both the Devices 

page and Zone Temperature Logging reports.
Each connected input is also assigned a Device Profile, which 

determines if an alarm is generated when the sensor reports 

a reading outside of the designated range.

7

Reports

The Zone Temperature Analysis report displays temperature 

and time as reported by a temperature sensor or thermostat. 

It also displays a histogram representing the time spent at 

various temperatures over the report time period.
When a time is selected on the histogram, the number of hours 

spent above or below the selected temperature also displays.

An input’s Device Profile can be configured to generate a 

threshold alarm when a temperature is outside of designated 

limits, as shown below. When an input is shorted or open, a 

failure alarm is raised against the device, as shown below.

Alert Emails

An Email Rule can be set up to automatically send an email 

when a temperature alarm is generated, or when other alerts 

occur. See Email Alert Rules in the CSM online help for more 

information.

8

Alarms

Summary of Contents for GE Current WSA10

Page 1: ...t and during Installation Test Mode red Joined On when the Wireless Adapter has joined a ZigBee network Flashes to indicate Reset and during sensor Installation Test Mode green Power On when power is applied to the Wireless Adapter green LED Indicators 1 Disconnect power to the 24V power supply before installation Confirm that power is off before continuing 2 IMPORTANT Use the provided Plan label ...

Page 2: ...ctions 0 10V sensors and NTC thermistors using a DC Power Supply Figure 3 WSA10 terminal connections for 0 10V sensors and NTC thermistors using a WFA100 SN for DC Power Supply NOTE WFA100 SN is inside an approved electrical fixture or enclosure to provide double insulation of the line voltage wiring ...

Page 3: ...or and NTC thermistors using a WGA100 or WA100 family adaptor for DC Power Supply Figure 5 WSA10 terminal connections for 0 10V sensors and NTC thermistors using an AC Power Supply adaptor for DC Power Supply To reduce AC noise on the sensor signal line install the AC to DC power supply near the WSA10 rather than near the sensor s ...

Page 4: ...h terminal can accept one conductor only Connect only one 24AWG to 16AWG wire to any terminal All installation and maintenance of line voltage equipment must be performed by a qualified electrician The WSA10 must be installed in accordance with all local state and national electrical codes and requirements If the sensor cable includes a shield terminate the end closest to the WSA10 as shown in the...

Page 5: ...SA10 or you can write the last 4 or 5 digits on the floor plan This information will be used during the commissioning process After the system installation is complete a marked up copy of the facility floor plan showing the identity and location of each wireless adapter including associated sensors should be available This will simplify and expedite the commissioning process After the WSA10 is pow...

Page 6: ...tside of the designated range 7 Reports The Zone Temperature Analysis report displays temperature and time as reported by a temperature sensor or thermostat It also displays a histogram representing the time spent at various temperatures over the report time period When a time is selected on the histogram the number of hours spent above or below the selected temperature also displays An input s De...

Page 7: ...temp Backup operation only Inputs Resistance 4 Thermistor 10K Type 2 Accuracy 0 5 C 10 C to 45 C 14 F to 113 F 1 C 30 C to 65 C 22 F to 149 F Voltage 2 0 10VDC Accuracy 2 of span without calibration Radio Properties 2 4 GHz 8 dBm Range dependent on RF propagation variables Operating Relative humidity 5 to 95 Environment non condensing Temperature 32 to 122 F 0 to 50 C Compliance US FCC Part 15 Can...