background image

Tetra

®

 Power Supply GEPS24-200U-GLX2

Installation Guide

2

Power Supply Installation

Connect the supply wire that is 

attached to your LED system to the red 

(+) and black (-) output wires of the 

LED driver as outlined in the “Electrical 

Connections” section of your LED 

system’s Installation Instructions.

Remove the junction box cover and 

carefully remove knockout for AC line 

input wires. Install appropriate electrical 

fittings in the knockout holes for wire 

protection.  Securely mount the power 

supply with the base in contact with the 

mounting surface in accordance with 

the power supply spacing requirements 

described above.  If used in a wet 

location, the power supply and electrical 

connections shall be protected from 

weather by a suitable rain enclosure, and 

not subject to saturation with water or 

other liquids. If not protected from the 

weather, the output connections may be 

sealed with electrical grade silicone.

Connect the AC line to the black 

(line) and white (neutral) input 

wires of the LED driver using 

18-14 AWG (0.82-2.08 mm

2

) twist-on 

wire connectors. Ground LED driver by 

connecting green wire to grounding 

screw. Replace junction box cover. 

White (neutral)

Black (line)

Green 

(ground)

AC line

To LED system

Output wires

NOTE: To avoid overloading this 

power supply with LED modules, 

please refer to the specific module 

loading guides.

FOR UL ONLY

NOTE: For CSA approval, a disconnect/toggle switch of appropriate rating needs to be placed within 29.5 ft. (9 m) of primary 

side of the power supply. The minimum rating of the switch must be either 120 or 220 Volts AC. The switch must also support 

twice the amount of input current.

FOR UL ONLY

NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device for line and 

neutral connections, in accordance with local, state or country regulations. 

FOR UL ONLY

NOTE: The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric 

Code (NEC) Article 600.

 

WARNING / AVERTISSEMENT

RISK OF ELECTRIC SHOCK

•  Disconnect power at fuse box or circuit breaker before servicing or 

installing product.

•  Properly ground Tetra

®

 power supply.

RISK OF FIRE

•  Minimum 4 in. to side and 1 in. spacing in compartment 

surrounding component required.

•  Use only approved wire for input/output connection. Minimum 

size 18 AWG (0.82 mm

2

).

•  Follow all local codes.

•  Application considerations potentially requiring additional spacing 

include high ambient temperature seen by the power supply, poor 

contact with a heat dissipating material, inadequate ventilation, or 

direct exposure to sun.

RISQUES DE DÉCHARGES ÉLECTRIQUES

•  Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant 

l’entretien ou l’installation du produit.

•  Assurez-vous de correctement mettre à terre le bloc d’alimentation Tetra

®

.

RISQUES D’INCENDIE

•  Minimum 4 po sur le côté et espacement de 1 po dans le compartiment 

entourant le composant requis.

•  N’utilisez que des fils approuvés pour les entrées/sorties de connexion. 

Taille minimum 18 AWG (0.82 mm

2

).

•  Respectez tous les codes locaux.

•  Certaines applications pourraient requérir un espacement additionnel, p. 

ex. une température ambiante élevée autour du bloc d’alimentation, un 

mauvais contact avec une matière dissipatrice de chaleur, une ventilation 

inadéquate ou une exposition directe au soleil. 

OPTIONAL 

A Weather Box (GEXNWB2) may be used to house and seal Class 2 

connections. 

A) Insert wire connectors into weather box. Fill with electrical grade 

silicone and close box. 

B) Secure the weather box using a #6 or #8 (M2 or M3) screw.

Weather box 

can be painted

Light engine

 

CAUTION / ATTENTION

RISK INJURY

•  While performing installations described, gloves, safety glasses or 

goggles should be worn.

RISQUES DE BLESSURE

•  Lors de l’exécution des installations décrites, des gants, des lunettes de 

sécurité ou des lunettes de protection doivent être portées.

1

2

3

A

B

Reviews: