8
Circuit Breaker
The Circuit breaker will automatically cut off the circuit if there is a short circuit or a
significant overload of the generator at the receptacle. If the circuit breaker is OFF
automatically, check that the appliance is working properly and does not exceed the rated
load capacity of the circuit before push to reset the circuit breaker.
ON OFF (PUSH TO RESET)
Ground Terminal
The generator ground terminal is connected to the frame of the generator, the metal
non-current carrying parts of the generator, and the ground terminals of each receptacle.
Before using the ground terminal, consult a qualified electrician, electrical inspector or local
agency having jurisdiction for local codes or ordinances that apply to the intended use of the
generator.
Oil Alert System
The Oil Alert system is designed to prevent engine damage caused by an insufficient
amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe
limit, the Oil Alert system will automatically shut down the engine (the engine switch will
remain in the "ON" position).
If the Oil Alert system shuts down the engine, add engine oil.
DC Outlet
The DC outlet is used only for charging a 12 Volt battery. It provides up to 12V-8.3A (100W)
of power.