background image

CD 

□ 

Main  AC  P

o

wer 

---switch 

-AC  P

o

wer

Juncti

o

n  B

o

xes

Encl

o

sure  Wall

� 

Fitting,  PAC  Seal,  1''NPT 

------M370-000006 

Rigid 

/C

o

nduit

S�c������Q���� 

�1-===��'.'.JC�

o

jt::::::::::::==:::1 

Sign a I  Cab I es 

-Only  in  this  C

o

nduit 

Packing  Fiber 

Sealing  C

o

mp

o

und 

Packing  Fiber,  C090-010000 

Nipple,  1 "NPT 

(2) � 

�PAC  Seal  Fittings

1"  NPT 

PAC  Seal  Fittings 

1"  NPT,  18"  max 

fr

o

m  Encl

o

sure 

MODEL  9026 

M360-000002 

PAC-SEAL  KIT,  1"  NPT 

REFER  TO  PAC-SEAL  INSTRUCTIONS 

TABLE 

MODEL 

LENGTH 

9565 

50' 

9566 

100' 

9567 

150' 

MODEL  9017:  DIVISION  2  Z-PURGE  MOUNTED  TO  AN  ENCLOSURE 

9568 

200' 

ENCLOSURE  WALL 

MODEL  9017:  DIVISION  2  Z-PURGE 

Pressure  Gauge,  0-160  PSI 

M340-000042 

Mechanical 

9569 

250' 

9570 

300' 

9571 

350' 

9572 

400' 

/

Shut  Off  Valve 

/  M390-000004 

� Pressure  Regulat

o

r,  0-100  PSI  NOTES:

/  M340-000171 

CD 

REFER  TO  ALL  LOCAL  CODES  FOR  CONDUIT  ENTRY  INFORMATION!

l==::::::f 

�===c::==:J:====l

�Pressure 

Relief  Valve 

2-125  PSI

M340-000043 

............. --�� 

MODEL  9047 

- Water  &  Oil  Separat

o

r

M340-000024

Dessicant  Refill

C040-000016

AIR  CONNECTION  KIT 

REFER  TO  AIR  CONNECTION  INSTRUCTIONS 

Filter 

DIMENSIONS  ARE  IN  INCHES 

Daisy Data, Inc. 

THIS  DOCUMENT  IS  PROPRIETARY  TO  DAISY  DATA,  INC. 

THE  USE  OF  OR  REPRODUCTION  OF  THIS  DOCUMENT 

IS  PROHIBITED  EXCEPT  AS  AUTHORIZED  BY 

2850  Lewisberry  Road,  York  Haven,  PA  17370 

DAISY  DATA  IN  WRITING.  SPECIFICATIONS  ARE 

ELECTRICAL INPUT DRAWING 

SUBJECT  TO  CHANGE  WITHOUT  NOTICE. 

CABLE 

THE  USER  ASSUMES  TOTAL  RESPONSIBILITY  FOR  COMPLIANCE  WITH  ALL  APPLICABLE 

CODES  &  PROCEDURES  IN  THE  FINAL  INSTALLATION . 
THE  PAC  SEAL  FITTINGS  CAN  BE  A  MAXIMUM  OF  18"  FROM  THE  ENCLOSURE. 

PAC  SEALS  MAY  BE  ATTACHED  DIRECTLY  TO  THE  ENCLOSURE  &  THE  RIGID  CONDUIT 

EXTENDED  IN  ANY  CONVENIENT  DIRECTION.  THE  PACKING  FIBER  &  THE  SEALING 

COMPOUND  MUST  COMPLETELY  SURROUND  EACH  CONDUCTOR  OR  CABLE. 
THE  AIR  INPUT  FITTING  IS  A  1/4"  NPT  FEMALE.  THE  AIR  SOURCE  MUST  BE  CLEAN 

DRY  INSTRUMENT  GRADE  AIR  CAPABLE  OF  SUPPLYING  35  TO  150  SCFH  AT  20  - 100  PSI. 
SEE  TABLE  1  FOR  THE  DAISY  DATA  CAT5  INPUT  CABLE 

MODEL  NUMBER  &  LENGTH. 

CONDUIT  ENTRY 

9017  Z-PURGED 

DRAWING  N

UMBP

l S

I

RE

� 

We Thrive in the Harshest Environments 

Voice:  (717) 932-9999  FAX:  (717) 932-8000  or Visit Us At www.daisydata.com 

SHEET 

OF 

1

P

age

 18

Daisy Data Displays, Inc.

Model 9017 Y/Z-Purge Operator Interface

Summary of Contents for 9017

Page 1: ...February 2022 Model 9017 Y Z Purge User Manual...

Page 2: ...requency energy and if not installed and used in accordance with the instructions in this manual may cause interference to radio communications Such equipment has been tested and found to comply with...

Page 3: ...purpose or other warranty of quality whether expressed or implied except of title and against patent infringement Correction of nonconformities in the manner and for the period of time provided above...

Page 4: ...Operation 9 5 1 Division 1 Y Z Purge Start Up Operation 9 6 Operation Notes 10 6 1 Division 1 Z Purge 10 7 1 Y Z Purge Ext Relay Kit Model 9121 12 7 1 1 Purge Types 12 7 1 2 General Y Z Purge Operati...

Page 5: ...ts This manual describes the general procedures for installing and operating DAISY Model 9017 Y Z Purge systems The text portion of the manual also includes an overview of the theory behind the method...

Page 6: ...assed through a given enclosure eliminate any possible flammable concentration of substances within the enclosure the minimum of four volumes of exchange still applies Factory Mutual Class Number 3620...

Page 7: ...eed the purge air or inert gas line to insure that dirt moisture and other contaminants are cleared from the line prior to connecting the line to the unit 5 Connect the purge gas line to the inlet of...

Page 8: ...should be illuminated green If not check the internal pressure it should be between 0 4 and 10 0 of Water Column The pressure good led must be illuminated green at this time If it is not please consu...

Page 9: ...om other conduits to prevent radiated or induced interference Devices that produce spikes surges and brownouts are detrimental to computers and can corrupt data and interfere with purging systems Do n...

Page 10: ...s 1 NPT or 0 75 NPT for the Z Purge or sealing conduits The PAC Seal and conduit size selected will depend on the size and number of conductors which must be run to the unit Check the NEC tables Chapt...

Page 11: ...F If accelerated curing is desired low temperature oven drying at 180 F can be used Do not expose the sealing compound to higher temperatures constant water immersion or steam environments while curi...

Page 12: ...separator or filter capable of supplying 150 SCFH at 20 100 PSI Fittings and tubing for purge air or inert gas supply 0 25 NPT Male to connect to the inlet of the purge system Local air pressure shut...

Page 13: ...lve to PURGE Make sure that the Flow Meter reads 150 SCFH If not readjust the regulator for 150 SCFH 6 The size of your enclosure will determine the purge time unless you purchased a Y Z Purge on a DA...

Page 14: ...in the red zone below 1 of water column the operator should immediately disconnect power and signal connections to the unit using switches in a safe area DAISY s Z purge systems are also equipped wit...

Page 15: ...ntact Daisy s customer service department Equipment returned to DAISY for service must be accompanied by a valid return merchandise authorization RMA number Anything shipped to DAISY without a valid R...

Page 16: ...the event of a loss of pressure within the enclosure the alarm system will indicate a failure The operator must then manually shut off power and signal connections at a safe disconnect location 7 1 3...

Page 17: ...Daisy Data Displays Inc February 2022 13 D011 000002 7 1 5 Model 9121 Block Diagram IMPORTANT The Model 9121 Relay Kit DOES NOT POWER DOWN THE ALARM CIRCUIT IN THE CABINET POWER TO THE PROTECTED EQUI...

Page 18: ...and free of oil a water oil separator should be installed near the connection to the purge control Restrictions in the purge line from the purge control into the enclosure Ensure that the purge line...

Page 19: ...plied to the enclosure after the internal pressure has reached 1 of water column or higher and when the full purge time has elapsed Insufficient internal pressure The pressure within the enclosure mus...

Page 20: ...W x 2 75 D 9 pounds Interface Box 7 25 H x 12 25 W x 3 50 D 5 pounds See drawing M012 for dimensions Environmental Operating Temperature 0 50 C Storage Temperature 0 70 C Relative Humidity 10 100 RH N...

Page 21: ...Number Description Page P015 Z Purge Cable Conduit Entry 18 M014 Z Purge Dimensions 19 M012 Z Purge Mounting 20 M017 Z Purge Mounting Options 21 P016 Z Purge Block Diagram 22 P017 Z Purge Front Panel...

Page 22: ...SIONS ARE IN INCHES Daisy Data Inc THIS DOCUMENT IS PROPRIETARY TO DAISY DATA INC THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTHORIZED BY 2850 Lewisberry Road York Haven PA 1...

Page 23: ...Page 19 Daisy Data Displays Inc Model 9017 Y Z Purge Operator Interface...

Page 24: ...Page 20 Daisy Data Displays Inc Model 9017 Y Z Purge Operator Interface...

Page 25: ...Page 21 Daisy Data Displays Inc Model 9017 Y Z Purge Operator Interface...

Page 26: ...Page 22 Daisy Data Displays Inc Model 9017 Y Z Purge Operator Interface...

Page 27: ...Page 23 Daisy Data Displays Inc Model 9017 Y Z Purge Operator Interface...

Page 28: ...Page 24 Daisy Data Displays Inc Model 9017 Y Z Purge Operator Interface...

Page 29: ...Model 9017 Y Z Purge Operator Interface Daisy Data Displays Inc Page 25...

Page 30: ...Model 9017 Y Z Purge Operator Interface Daisy Data Displays Inc Page 26...

Page 31: ...Model 9017 Y Z Purge Operator Interface Daisy Data Displays Inc Page 27...

Reviews: