30
INSTALLATION INSTRUCTIONS
Exhaust hose installation:
The exhaust hose and adaptor must be installed
or removed in accordance with the usage mode.
Fig. 19
Fig. 18
Fig. 17
Fig. 16a
Fig. 16b
COOL,HEAT(heat pump type) or
AUTO mode
Install
FAN,DEHUMIDIIFY or
HEAT(electrical heat type) mode
Remove
1. Install the adaptor B and adaptor I onto the
exhaust hose as shown in Fig.16a or Fig.16b.
Refer to the previous pages for window kit
installation.
2. Resert the hook of the Exhaust hose into the
hole seat of the air outlet and slide down the
Exhaust hose along the arrow direction (See
Fig.17) for installation.
The exhaust hose can be installed into the
wall
(Not applicable to the units without adaptor
A, expansion plugs and wooden screws of
Accessories ).
1. Prepare a hole in the wall. Install the wall
Exhaust adaptor A onto the wall(outside) by
using 4 expansion plugs and wooden screws,
be sure to fix thoroughly. (See Fig.18)
2. Attach the Exhaust hose to wall Exhaust
adaptor A.
Note:
Cover the hole using the adaptor cap when
not in use.
- The exhaust hose can be compressed
or extended moderately according to the
installation requirement, but it is desirable to
keep the hose length to a minimum.
IMPORTANT:
DO NOT OVER BEND THE EXHAUST HOSE
(SEE Fig.19)
CAUTION
Make sure that there is no obstacle around the
air outlet of the exhaust hose (in the range of
500mm) in order to the exhaust system works
properly.