Notices for installation
Earthing Requirements
1. Air conditioner is type I electric appliance. Please ensure that the unit is reliably earthed.
2. The yellow-green wire in air conditioner is the earthing wire which can not be used for other
purposes. Improper earthing may cause electric shock.
3. The earth resistance should accord to the national criterion.
4. The power must have reliable earthing terminal. Please do not connect the earthing wire with the
following:
1.-
Water pipe
2.-
Gas
3.-
Contamination pipe
4.-
Other place that professional personnel consider is unreliable
5. Including an air switch with suitable capacity, please note the following table. Air switch should
be included magnet buckle and heating buckle function, it can protect the circuit-short and overload.
(Caution: please do not use the fuse only for protect the circuit).
Air switch capacity
Air-conditioner (W)
25A
18
-
24K
-
20
-