Installation of Indoor Unit
Installation of Mounting Plate
1. Mounting plate should be installed horizontally. As the water tray’s outlet for the indoor unit is two-way
type, during installation, the indoor unit should slightly slant to water tray’s outlet for smooth drainage of
condensate.
2. Fix the mounting plate on the wall with screws.
3. Be sure that the mounting plate has been fixed firmly enough to withstand about 60 kg. Meanwhile, the
weight should be evenly shared by each screw.
18K UNIT:
24K UNIT:
694
52
194
298
256
Φ
55
Φ55
45
82
160
14
940
Fig.5
139
184
685
157
315
Φ70
Φ70
36
45
65
90
Drill Piping Hole
Indoor
Outdoor
1. Slant the piping hole (Φ55/70) on the wall slightly downward to the
outdoor side.
Wall pipe
Seal pad
2. Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
Φ
55/70
Installation of Drain Hose
1. Connect the drain hose to the outlet pipe of the indoor unit.
Bind the joint with rubber belt.
outlet pipe of
indoor unit
outlet pipe of
indoor unit
drain hose
rubber belt
2. Put the drain hose into insulating tube.
outlet pipe of
indoor unit
drain hose
rubber belt insulating tube
- 22 -