Page 15 of 62
SK2014
‐
SON
‐
002
‐
TechMnl
‐
FMCD
‐
003
B.1.3.
Installing
the
Mounting
Plate
1.
Select
the
structural
position
(e.g.
a
pillar
or
lintel)
on
the
wall.
2.
Then
temporarily
fasten
the
mounting
plate
on
the
wall
with
a
steel
nail.
3.
Mount
the
mounting
plate
horizontally
as
shown
in
the
above
figure
or
by
means
of
gradiometer.
Failure
to
follow
this
may
cause
water
to
drip
indoors
and
create
additional
noise.
4.
Fix
the
mounting
plate
by
means
of
expansion
screws
or
tapping
screws.
B.1.4.
Drilling
the
Condensate
Drainage
Hole
1.
Ensure
that
the
hole
for
condensate
drainage
is
correctly
positioned.
The
height
should
be
lower
than
the
bottom
edge
of
the
indoor
unit.
2.
Drill
a
65mm
diameter
hole
with
a
descending
slope.
3.
Seal
it
off
with
putty
after
installation.
Summary of Contents for FMCD*ECM series
Page 11: ...Page 11 of 62 Dimensional drawing for FMCD 20 24 ECM All dimensionsshown in mm ...
Page 21: ...Page 21 of 62 SK2014 SON 002 TechMnl FMCD 003 C 1 3 Wiring Diagram SK NCFMCD 001 ...
Page 45: ...Page 45 of 62 SK2014 SON 002 TechMnl FMCD 003 C 4 2 Wiring Diagram SK NCFMCD 002 ...
Page 62: ...Page 62 of 62 SK2014 SON 002 TechMnl FMCD 003 ...