HOW THE AIR CONDITIONER WORKS

TEMPORARY OPERATIONS

The air conditioner selects and operates in one of the
operating modes of cooling, heating (cooling only
type without) or fan only, depending on the room
temperature.
The air conditioner will control room temperature
automatically round the temperature point set by you.
If the Auto mode is uncomfortable, you can select the
desired conditions manually.

Set the TEMPORARY switch to the AUTO position in order
to start the automatic operation.
The COOL position is provided for test runs of the unit, and
automatic temperature control is cut off at this position.
Never use the position for ordinary operation.

When your push ECONO button during cooling, heating
(cooling only type without), or AUTO operation, the air
conditioner will start following operation. The fan speed
will be automatically controlled. In the operation suppression
zone where capacity is kept to the minimum, overcooling is
prevented by raising the temperature setting by 1 C after 1
hour and by 2 C after 2 hours of operation. The room
temperature is thus regulated between the operation
suppression zone and the set temperature. (It depends on
the outdoor temperature.)

The dry mode will automatically select the cooling dry
operation based on the difference between the set
temperature and the actual room temperature.

This function is used to operate the unit temporarily in case
you misplace the remote controller or its batteries are
exhausted.

The temperature is regulated while dehumidifying by
repeating turning on and off of the cooling operation or fan
only.
The fan speed indicator will display AUTO and low speed
will be used.

AUTOMATIC OPERATION

ECONOMIC OPERATION

DRY OPERATION

Temporary Operation

.
.

.

.

.

Cooling

Cool ing

Time

Dry

Indoor unit

I cannot find the
remote controller

A temporary
operation
feature
is provided

TEMPORARY Switch

COOL

AUTO

Room

temperature

set temperature

Cooling

operation suppression zone

2 hours

Set temperature

1 hours

1 C

2 C

ECONOMIC Operation

Fan only

Fan only

6

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

Summary of Contents for M3OA-27HRN1

Page 1: ...SPLIT TYPE Thank you very much for purchasing our air conditioner please read this owner s manual carefully before using your air conditioner save this manual in a safe place for future reference PDF 文件使用 pdfFactory Pro 试用版本创建 www fineprint cn ...

Page 2: ...OR UNIT CONTROLS ADJUSTING AIR FLOW DIRECTION HOW THE AIR CONDITIONER WORKS TEMPORARY OPERATIONS MAINTENANCE AIR CONDITIONER OPERATIONS AND PERFORMANCE INSTALLATION TROUBLES AND CAUSES TROUBLES AND CAUSES CONCERNING REMOTE CONTROLLER 1 2 3 4 5 6 6 7 9 10 11 12 PDF 文件使用 pdfFactory Pro 试用版本创建 www fineprint cn ...

Page 3: ...rections may result in a loss of oxygen in the room Never put hands or objects into the air outlet of indoor and outdoor units These units contain a fan running at high speed Touching the moving fan will cause serious injury To prevent electric shock turn off the power or disconnect the power supply plug before beginning any cleaning or other routine maintenance Follow the directions for cleaning ...

Page 4: ... to ensure that they do not play with the appliance Set moderate temperature especially when there are children old men or the disables in the room In cooling close the curtains to avoid direct sunlight Set the timer for the desired operation time Adjust air flow direction for even circulation of room air To keep cool or warm air in the room never open doors and windows more often than necessary M...

Page 5: ...ceiver 10 Remote Controller 11 Control panel 12 Drain hose refrigerant connecting pipe and electric wiring 13 Air inlet side and rear 14 Air outlet 15 接水盘 Indoor unit Outdoor unit 3 Operation Lamp Automatic Lamp Timer Lamp Economic Lamp Pre defrost Lamp Cooling only type without Infrared signal receiver Display panel OPERATION AUTO TIMER PRE DEF ECON 1 1 2 2 3 3 4 4 5 5 6 6 A2机 A1机 B机 PDF 文件使用 pdf...

Page 6: ...ition for temporary operation Opening the front panel Pull up from two ends of the front panel Open the panel and lift the panel up to an angle where it remains fixed Do not lift the panel any further when it stops with a clicking sound Closing the front panel Lower ends of the front panel push the ends on both sides Close the panel firmly Control panel Temporary Cool Temporary operation Auto 4 PD...

Page 7: ...ration return the vertical air flow louver to the original position using the AIR DIRECTION button on the remote controller The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in operation including when the ON TIMER is set Do not operate the air conditioner for long hours the air flow direction set downward during the cooling or dry operation Otherwise may occur o...

Page 8: ...ing is prevented by raising the temperature setting by 1 C after 1 hour and by 2 C after 2 hours of operation The room temperature is thus regulated between the operation suppression zone and the set temperature It depends on the outdoor temperature The dry mode will automatically select the cooling dry operation based on the difference between the set temperature and the actual room temperature T...

Page 9: ... from the filter holder Use a dry cloth to wipe the indoor unit and remote controller A cloth dampened with cold water may be used on the indoor unit if it is very dirty Never use a damp cloth on the remote controller Do not use a chemically treated duster for wiping or leave such materials on the unit for long It may damage or fade the surface of the unit Do not use benzine thinner polishing powd...

Page 10: ...he filter every month immerse the filter in the water with the mild detergent for 20 minutes and wash it slightly do not rub then expose it in the sun to dry it out for more than 3 hours put the black side face up 6 Install the filters into their support frames and set the support frames back in position The black side of the filters be at the outsides 7 Insert the AIR FILTER from the top side int...

Page 11: ...pproximately 5 minutes when the indoor heat exchanger warms up Warm air control When the room temperature reaches the set temperature the fan speed is automatically reduced to prevent a cold draft At this time the outdoor unit will stop Defrosting If the outdoor unit is frosted during heating operation defrosting is started automatically for approximately 5 to 10 minutes to maintain the heating ef...

Page 12: ...noise or vibrations The noise near the air outlet of the outdoor unit may enter the air exit Locate the outdoor unit where noise emitted by it or hot air from its air outlet will cause no nuisance to your neighbours If the air conditioner sounds abnormal during operation contact the dealer where your purchased the air conditioner To prevent the voltage please link the air conditioner with the floo...

Page 13: ...e clothing or furs are coming out A white mist of chilled air or water is generated from the outdoor unit Room air is smelly If any of the following conditions occur stop the air conditioner immediately set to off the power switch and contact the dealer The indicator lamps flash rapidly five times per second you disconnect the unit with the power and then connect the unit with the power again afte...

Page 14: ...t when the ON OFF button is pushed Direct the signal transmitter of the remote controller to the receiver of the indoor unit and then repeatly push the ON OFF button twice The temperature cannot be set during fan only operation The remote control signal is not transmitted even when the ON OFF button is pushed Check whether the ON TIMER is indicated on the display Check whether the MODE indicated o...

Page 15: ...CS266 U PDF 文件使用 pdfFactory Pro 试用版本创建 www fineprint cn ...

Reviews: