Product size:
Weight:4.2kg
Magazine Capacity:90PCS
Features
Light weight magnesium body reduces working fatigue.
Easy clear jam clearing.
Tool free depth of drive.
Fast fire speed.
No-Mar tip protects work surface.
Assembly/installation
Follow the instructions below to prepare your tool for operation.
1.All tool operators and their immediate supervisors must become familiar with the operator safety
instructions before operating the tool.
2.Included with each tool are one copy of these Operating/Safety Instructions. Keep this publications for
future reference.
3.Install a filter, regulator, lubricator unit and moisture trap on your air delivery system per the
manufacturer's instructions for these devices. Additionally, install a pressure gauge as close as practical to the
tool, preferably within 3M.
4.Select hoses with a minimum inner diameter of 1/4 inches and a maximum length of 3M.
Warning
To reduce the risk of injury from a hose bursting, select hoses that are rated at least 200PSI.
5.Select fittings that are appropriate size for the selected hoses. The tool and air hose must have a hose
coupling so that all pressure is removed from the tool when the coupling joint is disconnected.
Warning
Never use non relieving couplers and/or female quick disconnect couplings on the tool. Non relieving
couplings and female couplings will trap high pressure air in the tool when the air line is disconnected. This
will leave the tool charged with enough air after it has been disconnected to drive a nail. Only MALE
pneumatic type air connectors should be fitted to the tool, so that high pressure air in the tool is vented to
atmosphere as soon as the air line is disconnected.
6. Set the regulator at the air delivery system to a PSI that falls within the tool's operating range of 70-115PSI.
The correct pressure is the lowest pressure that will do the job.
Operation
Lubrication
Warning
Use only the air tool lubricants supplied with the tool. Do not use other lubricants as they may damage the
tool.
If the tool is not used with an in-line Lubrication system on the air supply it is necessary to periodically
lubricate the tool with air tool lubrication.
Under low use, lubricate once a day. Under heavy use, lubricate twice a day. To lubricate, insert 2-3 drops
of lubricant into the air supply fitting attached to the tool handle (FIG 2). Using too much oil will cause it to
collect in the tool and be noticeable in the exhaust.
Summary of Contents for XI3490
Page 1: ...USER MANUAL Heavy Duty Framing Nailer XI3490...
Page 2: ......
Page 85: ...85 Assembly Drawing...
Page 86: ...86 Parts List...
Page 87: ...87...
Page 88: ...88...
Page 89: ...89...
Page 90: ...90...
Page 91: ...91...
Page 92: ...92...
Page 93: ...93...
Page 94: ...94...
Page 95: ...95...
Page 96: ...96...
Page 97: ...97...