16
CONTROLLER TROUBLESHOOTING
Each controller has a self-diagnostic function built into its
memory for troubleshooting system failures. If the
Transplanter will not respond to signals sent by the transmitter
and the transmitter has proven to be working properly and
the incoming power to the receiver has been verified, check
for controller output faults by observing the red indicator light
on each controller upon start-up.
If an output fault has been detected, a series of flashes
will be given. Count the series and compare it to the following
codes. The series of flashes will be repeated three times. A
short pause will be present between the first and second
number. These codes indicate the particular circuit where
either an open or short exists.
Controller A (front)
4-1 Engine High Idle
4-2 Water Valve
4-3 Left Outrigger Extend
4-4 Left Outrigger Retract
4-5 Right Outrigger Extend
4-6 Right Outrigger Retract
4-9 Tilt Up
5-1 Tilt Down
5-2 Lift Up
5-3 Lift Down
5-4 Left Gate Open
5-5 Left Gate Close
5-6 Right Gate Open
5-7 Right Gate Close
Controller B (rear)
4-1 Left Leveler Up
4-2 Left Leveler Down
4-3 Right Leveler Up
4-4 Right Leveler Down
4-5 Left-Front Spade Up
4-6 Left-Front Spade Down
4-7 Right-Rear Spade Up
4-8 Right-Rear Spade Down
4-9 Right-Front Spade Up
5-1 Right-Front Spade Down
5-2 Left-Rear Spade Up
5-3 Left-Rear Spade Down
5-4 Left-Front Water Valve
5-5 Right-Rear Water Valve
5-6 Right-Front Water Valve
5-7 Left-Rear Water Valve
® ™ Trademarks of Dakota Peat, Inc.
407
Printed in USA