background image

Big Stream 2 Quick Guide

DD4734683
Rev 01
08 December 2020

201 Daktronics Drive

Brookings, SD 57006-5128

www.daktronics.com/support

800.325.8766

Page 2 of 12

Config Profiles

The system ships configured with a 720p output by default. 

 

To change the output resolution to 1080p: 

1. 

Open a web browser and go to http://192.168.0.237/#profiles to 

access the DMP-8000 

Config Profiles

 window. 

Note: 

If asked to enter login credentials, the defaults are 

Username

vnet

 and 

Password:

 

dakpassv

2. 

Select 

1080p NDI Ouput

3. 

Click 

Continue

 when the confirmation message opens. 

4. 

Wait for the player to restart. A green check mark indicates when 

the process is completed. 

Reusing Existing Content

In general, Daktronics recommends creating new content specifically 

for streaming using the correct output resolutions (720p = 720 x 1280 

or 1080p = 1080 x 1920). 
Depending on the size and aspect ratio of existing display content, 

it may be possible to reuse the files for streaming. Otherwise, the 

content may still need to be recreated. For example, if you have 

a small 132 x 176 display with a 4:3 aspect ratio, streaming its 

content will not only cause pixelation due to upscaling, it will also be 

stretched to fit the width, giving it more of a squished appearance: 

Before

132 x 176 (4:3)

After

720 x 1280 (16:9)

#8

#8

J A C O B S

J A C O B S

M I C H E L L E

M I C H E L L E

However, if you already have a display with a 16:9 aspect ratio, the 

content will better fit the aspect ratio of the streaming output. The 

content can still become pixelated, depending on how much it 

needs to upscale, but this can work if time or resources are limited 

before a scheduled event. 

Summary of Contents for Big Stream 2

Page 1: ...nd connections 3 Place the Show Control laptop on the top shelf of the rack case and use the plastic clamps to hold it in place 4 Route the supplied Cat5 network cable through the hole in the top of t...

Page 2: ...creating new content specifically for streaming using the correct output resolutions 720p 720 x 1280 or 1080p 1080 x 1920 Depending on the size and aspect ratio of existing display content it may be p...

Page 3: ...onnect the 25 BNC cable part W 1971 between a VIDEO OUT jack and the SDI INPUT jack on the rear of the rack c Connect the 1 8 to 1 4 adapter into the 1 8 TriCaster operator monitor audio cable and the...

Page 4: ...s the TriCaster acts as a switcher for up to 4 video inputs For the Big Stream system the TriCaster Mini may also function as the streaming device For more information about connections to the TriCast...

Page 5: ...Mix 4 is the replay mix MIX 2 will be used for the separate streaming mix a Change MIX 2 Video to M E 2 b Change STREAM 1 Video to MIX 2 c Adjust the Audio output source if desired 3 Click the STREAM...

Page 6: ...ok Press the Windows key and go to All Programs Daktronics Display Studio Show Control System User Handbook From within Display Studio press the Display Studio Hub button and select Help Watch the fol...

Page 7: ...USB COM1 NETWORK COMPUTER BY CUSTOMER NOTE DAKSTATS STATISTICS PROGRAM AND THE DSTI INTERFACE PROGRAMS MAY BE PURCHASED FROM DAKTRONICS STAT CREW STATISTICS PROGRAM IS PROVIDED BY OTHERS EXPANDED STA...

Page 8: ...P J BOX 2 X4 W 1247 25 TO FIBER CONVERTER CARD OR DIRECTLY TO SCOREBOARD 22AWG SHIELDED PAIR COPPER CABLE 2 15AMP DUPLEX RECEPTACLE BY CUSTOMER TO CUSTOMER STATCREW COMPUTER IF APPLICABLE ALTERNATE SH...

Page 9: ...430 2 TIME WARP 850TW REPLAY CONTROLLER A 3343 1 LAUNCHPAD MINI MK3 A 3450 1 TRICASTER MINI ADVANCED SDI A 4715564 1 TRICASTER MINI TRAVEL CASE EN 4715565 1 25 BNC VIDEO CABLE W 1971 1 ADAPTER 1 4 PLU...

Page 10: ...This page intentionally left blank...

Page 11: ...D102 NETWORK USB 1 USB 2 USB 3 SHOW CONTROL LAPTOP 0A 1453 7211 CPU 2 SCU 1 NOTES 1 FOR OPTIONAL HDMI INPUT CONNECT W 3896406 PATCH CABLE BETWEEN OUTPUT 1 AND SDI IN REFER TO FIGURE 1 2 FOR SDI INPUT...

Page 12: ...TO EN 1896 SHELF USING AT 1059 2 SECURE THE ROUTER S POWER SUPPLY IN THE OPEN SPACE OF THE DMP SHELF WITH AT 1059 TOP VIEW RACK REAR EN 1896 SHELF AT 1059 TOP VIEW VCV 1 24 18 50 EQUIPMENT LIST PART...