ADDITIONAL TherMOsTAT
There is a possibility to thermostat a room adjacent to the room where the stove is positioned: just connect a thermostat
following the procedure described in the next step (it is recommended to position the optional mechanical thermostat at a
height of 1.50 m from the floor) .
The default sTby function is always active (it cannot be disabled) and the sTby clamp is jumpered (contact closed).
ADDITIONAL TherMOsTAT FuNCTIONINg WITh sTby ACTIVe
When the contact or external thermostat is not satisfied (open contact
STBY
STBY
=temperature reached), the stove will switch off.
As soon as the contact or external thermostat switches to the "not satisfied" status (closed contact
STBY
STBY
= temperature to be
reached) it will re-ignite, after the boiler has cooled down.
N.B.: stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions. If
stove is in H OFF (water temperature reached), any additional contact or thermostat request will be ignored.
ADDITIONAL TherMOsTAT INsTALLATION
Switch the appliance off using the master switch positioned on the rear of the stove.
Remove the plug from the socket.
Refer to the electrical diagram to connect the two thermostat cables onto the relative clamps positioned on the rear of the
machine, one is red and the other one is black (STBy clamp).
The image is given as an example.
J
N.b. : INsTALLATION MusT be PerFOrMeD by AN AuThOrIseD TeChNICIAN
ATTeNTION:
The CLAMP MusT be FITTeD WITh A "Dry" TyPe CONTACT
(INPuT WITh Dry CONTACT, POTeNTIAL-Free)
J
The sTby AND Aux
CLAMPs, FOuND AT The
bACK OF The sTOVe
CAN be NOTeD IN The
DIAgrAM AT The sIDe
Aux
Connection reserved for Dal Zotto
conveyed waves accessories.