ENGLISH
ROUTINE MAINTENANCE CARRIED OUT BY AUTHORISED TECHNICIANS
Routine maintenance must be performed at least once a year.
As the generator uses pellets as solid fuel, it needs an annual routine maintenance interval that needs to be performed by an
authorised
technician by only using original spare parts.
Failure to do so can affect the appliance's safety and you may no longer be entitled to the warranty conditions.
By following the cleaning schedule reserved to the user and reported in the user and maintenance manual, one ensures correct combustion
in the generator over time, thereby preventing any anomalies and/or malfunctions that may require more work to be performed by the
technician. Requests for routine maintenance are not covered by the product's warranty.
DOOR, ASH DRAWER AND BURN POT GASKETS
The gaskets ensure the tightness of the stove and its consequent proper operation.
They must be checked periodically: in the event they are worn or damaged they must be replaced immediately.
These operations must be carried out by a qualified technician.
CONNECTION TO THE FLUE
Vacuum and clean the pipe that leads to the flue yearly or whenever necessary. If there are horizontal sections, any residue must be removed
before it obstructs the flue.
PUTTING THE EQUIPMENT OUT OF SERVICE (END OF THE SEASON)
At the end of every season, before turning off the stove, we recommend completely emptying the pellet tank and using a vacuum cleaner to
clear up any pellets and dust residue inside it.
WE ADVISE YOU NOT TO DISCONNECT THE GENERATOR FROM THE ELECTRICAL POWER SUPPLY, SO AS TO ALLOW THE PUMP TO PERFORM
THE NORMAL ANTI-LOCKING CYCLES.
Routine maintenance must be performed at least once a year.
IF THE POWER SUPPLY CABLE IS DAMAGED, IT MUST BE REPLACED BY THE AFTER-SALES SERVICE OR BY A SIMILARLY
QUALIFIED PERSON, SO AS TO AVOID ALL RISKS.
MONTHLY - JOLE IDRO 2.0
Remove the ash accumulated at the top of the hearth wall (see figure below)
54