ENGLISH
DISPLAYS
DISPLAY
REASON
OFF
Generator off
START
The start-up phase is in progress
PELLET FEEDING
Continuous pellet feeding is in progress during the ignition phase
IGNITION
The ignition phase is in progress
START-UP
The start-up phase is in progress
WORK
The normal work phase is in progress
MODULATION
The generator is working at minimum
BURN POT CLEANING
Automatic burn pot cleaning is in progress
*BURN POT CLEANING
DEPRESSION
Automatic burn pot cleaning is in progress - due to insufficient depression.
FINAL CLEANING
The final cleaning is in progress
STAND-BY
Generator off waiting for re-ignition due to an external thermostat
STAND-BY
COOLING
A new ignition is attempted when the generator has just been switched off. When the generator switches off, one must wait for
the complete shutdown of the fumes motor, then clean the burn pot. The generator can only be re-ignited when these operations
have been performed.
HOFF
Generator off due to water temperature over set.
*T-AMB
Displays room temperature (in the models designed for it).
*T - OFF
Generator off waiting for re-ignition as all the requests have been satisfied
STAND-BY
BLACK OUT
The generator is cooling after a power cut.
Once cooling is completed it will re-start automatically
ANTI-FREEZE
The anti-freeze function is in progress as the H2O t° is below the factory set threshold
the pump is active until the water reaches the pre-set factory par2°C
ANTILOCK
The pump antilock function is in progress (only if the generator has been in an OFF state for at least 96 hours); the pump is
activated for the time pre-set by the manufacturer, in order to prevent it from blocking
AUTO BLOW
The automatic blow is active
*EXCHANGER BLOCK
Automatic exchanger cleaning is blocked
ALARMS
DISPLAY
EXPLANATION
SOLUTION
Indicates the presence of an alarm.
On: indicates the presence of an alarm
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset by pressing key 1/
for 3 seconds only if the fumes motor
has stopped and if 15 minutes have elapsed from when the alarm was displayed.
ASPIRATION
FAULT
Fumes motor fault
Contact after-sales centre
* on applicable models.
56